Operating Environment; Cabling; Terminal Connectors - Motorola MPMC202 Installation And Use Manual

Fast
Table of Contents

Advertisement

Operating Environment

The MPMC202 requires the following operating environment:
Operating temperature
Storage temperature
Operating humidity, non-condensing
Storage humidity, non-condensing
Forced air cooling is not required when the ambient temperature is
below 40 degrees C. Above 40 degrees C, forced air cooling is
required.

Cabling

Motorola recommends using Category 5 UTP cabling, even if you
have a 10Mbps network. This allows you to upgrade the network to
100Mbps without needing to replace the existing cables.
Category 3 and 4 cabling supports 10Mbps operation. Category 5
cabling is required for 100Mbps operation.
Category 5 cabling supports Ethernet 802.3, 10Base-T, and Token
Ring 802.5 (4MB, 16MB). Category 5 supports 100 meters of cable
length between stations, and uses data grade modular wall outlets
and patch cables.
The MPMC202 is compliant with the 100 meter requirement of the
TP-PMD specification.

Terminal Connectors

Category 5 data grade cable requires discrete modular data grade
terminal connectors that plug into a panel or wall jack. When
routing Category 5 cable, use data grade connectors instead of
punchdown blocks.
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Cabling
0û to 55ûC
-40û to 85ûC
10-90%
5-95%