Page 3
Information in this Technical Manual is subject to change without notice due to correction or enhancement. The information described in this manual is the property of Anyload Weigh & Measure Inc. All other brand or product names within this publication are trademarks or registered trademarks of their respective companies.
Technical Manual | 808AH V1.2 INTRODUCTION EATURES Designed by Anyload Weigh & Measure Inc. in Canada Six digits LED industrial remote display. • High intensity, wide viewing angle, double row discrete LEDs. • Standard seven segments with capability to display alphanumerical characters.
7.5 kg (17 lb) main unit and 1.5 kg (3 lb) mounting kits, approximately Industry Approvals UL / CUL approved class II power supply, CB CE Limited Warranty 2 years limited Anyload Weigh & Measure Inc. @ www.anyload.com | INTRODUCTION...
Any installation and wiring must be handled by authorized personnel NOTICE! Refer to the local electrical code for the wiring color codes Refer to the installation section for instructions to how to access to the wiring terminals INSTALLATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
The enclosure is a weather proof mild steel powder coated with both standard pole mount and wall mount brackets included in the package. All internal parts are installed on a folding metal plate mounted inside of the enclosure. Anyload Weigh & Measure Inc. @ www.anyload.com | INSTALLATION...
To open the cover, unlatch the two toggle latches on both sides of the enclosure and flip down the hinged front cover. To access the electronic components, loosen two retention screws on each sides of the electronic plate of the 808AH remote display. INSTALLATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
The pole mount kit includes two ear mount pieces (connected to the main enclosure by six Philips screws) and a pole mount. Have the pole mount fixed on the pole first, then install the enclosure (with the ear mount pieces attached) on it. Anyload Weigh & Measure Inc. @ www.anyload.com | INSTALLATION...
Availability of the options is subject to confirmation by manufacturer and may vary by firmware version Refer to the configuration section for instructions on how to configure the functions of remote display Refer to the installation section for instructions on how to access the wiring terminals WIRING | Anyload Weigh & Measure Inc. @ www.anyload.com...
Any installation and wiring must be handled by authorized personnel NOTICE! Refer to the local electrical code for the wiring color codes Refer to the installation section for instructions to how to access to the wiring terminals Anyload Weigh & Measure Inc. @ www.anyload.com | WIRING...
Refer to the F4 section for instructions on how to configure passive or active mode of 20mA port Refer to the installation section for instructions on how to access the wiring terminals WIRING | Anyload Weigh & Measure Inc. @ www.anyload.com...
Page 13
Refer to the F2 section for instructions on how to configure multiple remote displays Refer to the F4 section for instructions on how to configure echo out ports Refer to the installation section for instructions on how to access the wiring terminals Anyload Weigh & Measure Inc. @ www.anyload.com | WIRING...
The switch and relay functions are disabled as default Refer to the configuration section for instructions to how to configure inputs and outputs Refer to the installation section for instructions to how to access to the wiring terminals WIRING | Anyload Weigh & Measure Inc. @ www.anyload.com...
It is useful if auto learn mode has not been successful or display is not aligned correctly. MANUAL Then it can be used to set communication rate and string format manually. Onboard FUNCTION LED will blink slowly once every two seconds. Anyload Weigh & Measure Inc. @ www.anyload.com | CONFIGURATION...
Long Press: Returning to section categories FX. Short press: FX.X + 0.1 RIGHT : Long press: Short Press: Increments subsection categories, FX.X. FX.X + 1.0 Long Press: Increments section categories, FX. CONFIGURATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
Page 17
A SAVED • E XITING ETUP message will be displayed and then it will reset. To exit without saving, press and hold TEST button. & Long Press Anyload Weigh & Measure Inc. @ www.anyload.com | CONFIGURATION...
Filter Display 0.50 0.5 sec It can be used based on sensitivity of the indicator. 0.75 0.75 sec It can be used combined with blank on motion function. 1.00 1 sec CONFIGURATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
The display will show OVER if weight is out of the set range. 999999 999999 Use short and long press keys to change value and digit respectively. If set to 000000, the Over Range function is off. Anyload Weigh & Measure Inc. @ www.anyload.com | CONFIGURATION...
It determines over / under load conditions. Over Load It searches O in string. It searches C in string. It searches E in string. If set None, over cap is off. CONFIGURATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
Set to passive mode if the indicator supplies current as default. Active Mode Set to active mode if the indicator is in passive mode. To use this function refer to indicator user manual for proper setting. Anyload Weigh & Measure Inc. @ www.anyload.com | CONFIGURATION...
It shows predefined messages on display if SW2 is not disabled. Switch 2 Refer to the wiring chapter and switch section of the manual. Message Default messages are as follows: OPEN STOP HALT QUIT CONFIGURATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
Fuse is rated at 5A/250V slow blow glass type Refer to the troubleshooting diagnostic lights and push buttons section for more information Refer to the configuration section for more information on advance diagnostic Anyload Weigh & Measure Inc. @ www.anyload.com | TROUBLESHOOTING...
Shows version number LOCK LOCK Loads protocol and baud from stored values Locks to latest successful configuration Avoids unnecessary delays at start up Locks if learn is successful at start up TROUBLESHOOTING | Anyload Weigh & Measure Inc. @ www.anyload.com...
Displays software version Version F9.7 XX-XX None Displays model number Model F9.8 Reserved None Protocol Alternative setup reset F9.9 Abort Reset Initialize Resets all setup values to default, except string settings Anyload Weigh & Measure Inc. @ www.anyload.com | TROUBLESHOOTING...
This is useful in axle weighing programs, totalizing indicators, and multi scale programmable indicators. An example of string protocol for multiple remote display application including address identifier is illustrated below. TROUBLESHOOTING | Anyload Weigh & Measure Inc. @ www.anyload.com...