Anyload 808 Series Technical Manual

Industrial remote display
Hide thumbs Also See for 808 Series:

Advertisement

Quick Links

Technical Manual | 808AH V1.2
Technical Manual
The 808 Series Industrial Remote Display

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 808 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Anyload 808 Series

  • Page 1 Technical Manual | 808AH V1.2 Technical Manual The 808 Series Industrial Remote Display...
  • Page 2: Table Of Contents

    Controller Board ............................21 Error Codes ..............................22 Display Messages ............................22 Push Buttons ..............................22 Diagnostic Lights ............................23 Advance Diagnostic ............................23 Protocol Example ............................24 Multiple Display ............................. 24 | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 3 Information in this Technical Manual is subject to change without notice due to correction or enhancement. The information described in this manual is the property of Anyload Weigh & Measure Inc. All other brand or product names within this publication are trademarks or registered trademarks of their respective companies.
  • Page 4: Introduction

    Technical Manual | 808AH V1.2 INTRODUCTION EATURES Designed by Anyload Weigh & Measure Inc. in Canada Six digits LED industrial remote display. • High intensity, wide viewing angle, double row discrete LEDs. • Standard seven segments with capability to display alphanumerical characters.
  • Page 5: Technical Specifications

    7.5 kg (17 lb) main unit and 1.5 kg (3 lb) mounting kits, approximately Industry Approvals UL / CUL approved class II power supply, CB CE Limited Warranty 2 years limited Anyload Weigh & Measure Inc. @ www.anyload.com | INTRODUCTION...
  • Page 6: Installation

    Any installation and wiring must be handled by authorized personnel NOTICE! Refer to the local electrical code for the wiring color codes Refer to the installation section for instructions to how to access to the wiring terminals INSTALLATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 7: Main Enclosure

    The enclosure is a weather proof mild steel powder coated with both standard pole mount and wall mount brackets included in the package. All internal parts are installed on a folding metal plate mounted inside of the enclosure. Anyload Weigh & Measure Inc. @ www.anyload.com | INSTALLATION...
  • Page 8: Opening Enclosure

    To open the cover, unlatch the two toggle latches on both sides of the enclosure and flip down the hinged front cover. To access the electronic components, loosen two retention screws on each sides of the electronic plate of the 808AH remote display. INSTALLATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 9: Wall Mounting

    The pole mount kit includes two ear mount pieces (connected to the main enclosure by six Philips screws) and a pole mount. Have the pole mount fixed on the pole first, then install the enclosure (with the ear mount pieces attached) on it. Anyload Weigh & Measure Inc. @ www.anyload.com | INSTALLATION...
  • Page 10: Wiring

    Availability of the options is subject to confirmation by manufacturer and may vary by firmware version Refer to the configuration section for instructions on how to configure the functions of remote display Refer to the installation section for instructions on how to access the wiring terminals WIRING | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 11: Electrical Power Wiring

    Any installation and wiring must be handled by authorized personnel NOTICE! Refer to the local electrical code for the wiring color codes Refer to the installation section for instructions to how to access to the wiring terminals Anyload Weigh & Measure Inc. @ www.anyload.com | WIRING...
  • Page 12: Serial Communication Wiring

    Refer to the F4 section for instructions on how to configure passive or active mode of 20mA port Refer to the installation section for instructions on how to access the wiring terminals WIRING | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 13 Refer to the F2 section for instructions on how to configure multiple remote displays Refer to the F4 section for instructions on how to configure echo out ports Refer to the installation section for instructions on how to access the wiring terminals Anyload Weigh & Measure Inc. @ www.anyload.com | WIRING...
  • Page 14: Switch And Relay Wiring

    The switch and relay functions are disabled as default Refer to the configuration section for instructions to how to configure inputs and outputs Refer to the installation section for instructions to how to access to the wiring terminals WIRING | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 15: Configuration

    It is useful if auto learn mode has not been successful or display is not aligned correctly. MANUAL Then it can be used to set communication rate and string format manually. Onboard FUNCTION LED will blink slowly once every two seconds. Anyload Weigh & Measure Inc. @ www.anyload.com | CONFIGURATION...
  • Page 16: Membrane Keypad

    Long Press: Returning to section categories FX. Short press: FX.X + 0.1 RIGHT : Long press: Short Press: Increments subsection categories, FX.X. FX.X + 1.0 Long Press: Increments section categories, FX. CONFIGURATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 17 A SAVED • E XITING ETUP message will be displayed and then it will reset. To exit without saving, press and hold TEST button. & Long   Press Anyload Weigh & Measure Inc. @ www.anyload.com | CONFIGURATION...
  • Page 18: F1 Display Setting

    Filter Display 0.50 0.5 sec It can be used based on sensitivity of the indicator. 0.75 0.75 sec It can be used combined with blank on motion function. 1.00 1 sec CONFIGURATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 19: F2 Utility Setting

    The display will show OVER if weight is out of the set range. 999999 999999 Use short and long press keys to change value and digit respectively. If set to 000000, the Over Range function is off. Anyload Weigh & Measure Inc. @ www.anyload.com | CONFIGURATION...
  • Page 20: F3 Protocol Setting

    It determines over / under load conditions. Over Load It searches O in string. It searches C in string. It searches E in string. If set None, over cap is off. CONFIGURATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 21: F4 Communication Setting

    Set to passive mode if the indicator supplies current as default. Active Mode Set to active mode if the indicator is in passive mode. To use this function refer to indicator user manual for proper setting. Anyload Weigh & Measure Inc. @ www.anyload.com | CONFIGURATION...
  • Page 22: F5 Auxiliary Setting

    It shows predefined messages on display if SW2 is not disabled. Switch 2 Refer to the wiring chapter and switch section of the manual. Message Default messages are as follows: OPEN STOP HALT QUIT CONFIGURATION | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 23: Troubleshooting

    Fuse is rated at 5A/250V slow blow glass type Refer to the troubleshooting diagnostic lights and push buttons section for more information Refer to the configuration section for more information on advance diagnostic Anyload Weigh & Measure Inc. @ www.anyload.com | TROUBLESHOOTING...
  • Page 24: Error Codes

    Shows version number LOCK LOCK Loads protocol and baud from stored values Locks to latest successful configuration Avoids unnecessary delays at start up Locks if learn is successful at start up TROUBLESHOOTING | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 25: Diagnostic Lights

    Displays software version Version F9.7 XX-XX None Displays model number Model F9.8 Reserved None Protocol Alternative setup reset F9.9 Abort Reset Initialize Resets all setup values to default, except string settings Anyload Weigh & Measure Inc. @ www.anyload.com | TROUBLESHOOTING...
  • Page 26: Protocol Example

    This is useful in axle weighing programs, totalizing indicators, and multi scale programmable indicators. An example of string protocol for multiple remote display application including address identifier is illustrated below. TROUBLESHOOTING | Anyload Weigh & Measure Inc. @ www.anyload.com...
  • Page 27 Type B .... GR, NT, lb, kg......ENGINEERED IN CANADA 808AH651-02RCC..Type I .... GR, NT, kg, t......808AH651-02RF..Type F ..GR, NT, kg, t......9.0 www.anyload.com © 2019 ANYLOAD V3 dimensions and specifications subject to change without notice...
  • Page 28 Technical Manual | 808AH V1.2 Please Contact our Authorized Dealer for Technical Assistance: Anyload Weigh & Measure Inc. North America Toll Free: 1.855.ANYLOAD (269.5623) Email: info@anyload.com www.anyload.com...

This manual is also suitable for:

808ah

Table of Contents