Installation

NOTICE
Do not over tighten tank level monitor into tank
bung! Over tightening can cause permanent dam-
age and result in inaccurate readings.
Do not use thread sealant or adhesive! Many of
these products are chemically incompatible with the
PC/ABS plastic.
Use the Graco-supplied down tube 15U731 only. Do
not replace down tube with any other tube.
1. Remove the bung fitting and screw in the TLM
hand-tight. DO NOT use a wrench to tighten as this
may damage the TLM. Do not use thread lock adhe-
sive as this may damage the TLM.
2. The TLM must be mounted within 2 degrees from
perpendicular to the surface of the fluid. A level that
measures degrees should be used. Place the level
on the top of the pipe fitting on the tank. If outside
the 2 degree specification, the fitting should be
changed.
Graco recommends that the height of the tank fitting
should not exceed 1/2 in. (1.27 cm). The fitting
height can be up to 2 in. (5.08 cm), provided the fit-
ting is within 2 degrees of the surface of the fluid.
Also, the taller the tank, the more critical the 2
degree specification becomes. See F
NOTICE
The TLM will not operate correctly if tilted more than
2° from the surface of the tank liquid.
The TLM will not read properly if:
-
Fluid in the tank is agitated (i.e. filling a tank
with oil or anti-freeze). Be sure to take all TLM
readings when the fluid in the tank is calm.
-
TLM is mounted next to the tank wall or in a cor-
ner.
-
If there is any structural bracing or obstruction
between the TLM and the surface of fluid in
tank.
-
If the down tube is not the Graco-supplied down
tube.
312964C
F
. 6
IG
Do not install the TLM in the tank's fill port. Repeated
removal of the TLM will damage the unit and void the
warranty.
Port (D) is not to be used as a fill hole for oil deliveries.
See F
The tank's breather port might be the only available
location for mounting the TLM. The horizontal 2 in. npt
.
. 6
IG
port (D) can be used to accommodate the breather. The
breather should be mounted in an upright position using
a 90° elbow fitting.
Do not use the horizontal port for routing pressure
relief return tubes. This can result in inaccurate
readings.
F
. 7
IG
TLM must be mounted with-
in 2° from perpendicular to
the surface of the fluid.
NOTICE
. 7.
IG
D
Installation
ti12034a
9