Page 1
599DGT-A/20 ISTRUZIONI PER L’USO INSTRUCTIONS FOR USE MODE D’EMPLOI NL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG INSTRUCCIONES INSTRUÇÕES DE USO INSTRUKCJA OBSLUGI HASZNÁLATI ÚTMUTATÓ...
Page 2
INSTRUCTIONS BETA 599 DGT-A/20 Electronic torque wrench Direct torque and angle readout MAIN FEATURES – Digital driving torque and angle readout – +/- 2% and +/- 2° accuracy (90° rotation at a rate of 30°/sec) – CW and CCW operation –...
Drive Setting (mm) (N-m) (inches) Range (N-m) 599 DGT-A/20 40-200 1/2” 10-200 Beta 599 DGT-A/20 Accuracy CW: ±2% CCW: ±2% Operation Mode Peak Hold / Track “ ° “ Unit Selection N-m, ft-lb, in-lb, kg-cm Head Type Reversible ratchet Gear Teeth...
Page 4
– Usually press to reset the digital torque wrench before using it. ATTENTION: If an external force is applied to the torque wrench during the power-on/reset or wake up period, an initial torque offset will be found in the memory. IMPORTANT: When the wrench is used in the “angle”...
Page 5
The wrench will start working again after a few seconds; however, it should be checked for Presetting Unit: Nm calibration at a Beta authorized centre as soon as possible. Press 2. The function “Unit Selection” is sequential...
Page 6
The wrench will start working again after a few seconds; however, it should be checked for calibration at a Beta authorized centre as soon as possible. 2. If you apply torque over 5 N-m, the LCD display will start to display the torque value. If the applied torque is less than 5 N-m, the LCD display does not show any changes in value.
Page 7
The wrench will start working again after a few seconds; however, it should be checked for calibration at a Beta authorized centre as soon as possible. 2. The green LED will be on for 90% of maximum setting torque.
Page 8
VALUE STORAGE IN PEAK HOLD MODE *Note 1 Peak/track mode Keep pressed *Note 2 Peak/track mode selection Press Automatic change Storage n°. Storage value *Note 3 Press Delete stored value Press Note: (Quit) 1. The value storage system, “peak mode”, can be used for the “track (Delete) Deleted mode”...
Page 9
ANGLE READOUT MODE OPERATON *Note 1 Angle mode Press *Note 2 *Note 3 Blinking Apply force and turn wrench Release Current torque Current angle * Nota 4 Over 80% of set value ((…((… …)) …)) 80% of set value reached *Note 5 Set value reached Release...
Page 10
SELECTING TORQUE UNIT OF MEASUREMENT IN ANGLE MODE *Note 1 Angle mode Keep pressed Peak/track mode Press Selecting unit of measurement: N-m Press Selecting unit of measurement: in-lb Press Selecting unit of measurement: ft-lb Press Selecting unit of measurement: kg-cm Note: 1.
CONNECTING CABLE Turn off the torque wrench and connect the cable to the PC and the wrench. DATA UPLOAD Select the “Send” mode on the wrench. (See section “Value storage in peak hold mode”) Insert the CD-ROM into the computer and start the data upload programme. ...
10. Do not apply any force to the LCD panel. BATTERY MAINTENANCE 1. When the Beta 599 DGT-A/20 wrench is not used for an extended period of time, remove the battery. 2. Keep a spare battery on hand when going on a long trip or to cold areas.
Need help?
Do you have a question about the 599 DGT-A/20 and is the answer not in the manual?
Questions and answers