CATIA (v.5)
2 Translation ON/OFF
3 Rotation ON/OFF
5 Dominant Mode ON/OFF
6 Increase Sensitivity
7 Default Sensitivity
Pro/ENGINEER (v.17 through 19)
1 Repaint.
Repaints the current screen.
2 Shade.
The object onscreen is shaded.
3 Display Datum.
Toggles the display of the
datum planes.
4 Model Spin Center.
the spin center axis.
5 Decrease Sensitivity
6 Increase Sensitivity
7 Default Sensitivity
8 Default View.
Resets the object to the default
view.
NOTE: See also the Pro/ENGINEER user's
manual under the cross reference View Point
Function or Spaceball .
Pro/ENGINEER (v.20 or higher)
1 Repaint.
Repaints the current screen.
2 Shade.
The object onscreen is shaded.
3 Previous View.
Resets the object to the
previous view.
4 Default View.
Resets the object to the default
view.
5 Gain Up
6 Gain Down
7 Gain Default
8 Refit.
Resizes the view of the object while
maintaining the current orientation.
NOTE: See also the Pro/ENGINEER user's
manual under the cross reference View Point
Function or Spaceball.
Unigraphics (v.11 or higher)
1 Translation ON/OFF
2 Rotation ON/OFF
3 Dominant Mode ON/OFF
4 Keep In View.
Pressing this key makes it
impossible to lose the graphical object outside
the bounds of the screen. The default is OFF.
5 Gain Down
6 Gain Up
The model will spin about
7 New Rotation Center.
rotation center at the center of the current
screen.
8 Menu.
Brings up the Unigraphics menu.
NOTE: See also the Unigraphics user's manual
under the cross reference View Point Function
or Magellan .
Second-Level Keyboard
Functions of the second-level keyboard are
executed by pressing any one of the eight
numerical keys in combination with the star
key. The keys must be pressed simultaneously .
Press and hold the star key followed by the
desired numerical key. Note that second-level
keyboard functions are not application-
dependent.
* 1 Translation ON/OFF
* 2 Rotation ON/OFF
* 3 Dominant Mode ON/OFF
* 4 Zeroing.
The Magellan/SPACE MOUSE is
zeroed at the current position of the cap. All
subsequent inputs are relative to this position.
* 5 Translation Sensitivity.
sensitivity is increased incrementally on a scale
from zero (the default) to 7. Activating this key
sequence the eighth time resets the sensitivity
to zero.
* 6 Rotation Sensitivity.
sensitivity is increased incrementally on a scale
from zero (the default) to 7. Activating this key
sequence the eighth time resets the sensitivity
to zero.
* 7 Zero Radius.
the cap required to cause movement is
increased incrementally on a scale from zero to
15 (the default). After 15 the setting is reset to
zero. A high zero radius setting is helpful if slight
vibrations exist in the work environment.
* 8 Default Sensitivity.
and rotational sensitivities and the zero radius to
the default settings.
Quicktip
A Quicktip is executed by pressing downward
on the cap with a quick tipping motion of your
finger, as shown below. The Quicktip function
11
Sets the new
The translational
The rotational
The minimum displacement of
Returns the translational
Need help?
Do you have a question about the LogiCad3D Magellan/SPACE MOUSE Classic and is the answer not in the manual?