Carbon monoxide detector

Advertisement

Temperature range: -10° to +40°C.
Sensitivity:
50ppm within 90 minutes
100ppm within 30 minutes
300ppm within 3 minutes
Audible Alarm Output:
85dB at 3m
All alarms are calibrated, tested and design to meet the stringent
performance requirements of the latest European standard for
domestic gas alarms - BS EN50291:2001
The Alarm is calibrated at the factory and does not need
recalibration. Do not tamper with the inside of the case or electric
shock or malfunction may occur.
No user maintenance or adjustment is required.
WARNING AND LIMITATION
This detector may not alarm at low carbon monoxide levels. The
Occupational
Safety
and
established that continuous exposure levels of 30 ppm should not
be exceeded in an 8 hours period. Individuals with a medical
problem may consider more sensitive detection devices.
The CO gas detector is not suitable as a smoke or fire detector.
This detector is not suitable to install in a hazardous location, as
defined in the National Electrical Code.
This detector will not work without power. The Carbon Monoxide
Detector will not work if the power supply is disconnected or cut off
or remove the batteries for any reason. Additionally, carbon
monoxide must reach the detector for the proper performance of
CO gas detection.
Carbon monoxide detectors may wear out because they contain
electronic parts that fail at any time. Test your detector at least
every week (see the section "TESTING YOUR DETECTOR").
SERVICE OR REPAIR INFORMATION
For service or repair, return your Zeta CO 200 Carbon Monoxide
Detector intact, stating the reason for return and details of any
fault, to the distributor who supplied the product.
Health
Association
(OSHA)
has
- 4 -