Advertisement

Quick Links

User Guide of ZT-30P
Flame Detector
Model: ZT-30P
User Guide
Document Ref: GLT-300-7-1
Zeta Alarms Limited
72 – 78 Morfa Road, Swansea, SA1 2EN, United Kingdom
Phone: +441792 455 175
Fax: +441792 455 176
Website:
www.zetaalarmsystems.com
Email:
info@zetaalarmsystems.com
1
Issue 1 / Rev.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZT-30P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zeta ZT-30P

  • Page 1 User Guide of ZT-30P Flame Detector Model: ZT-30P User Guide Document Ref: GLT-300-7-1 Zeta Alarms Limited 72 – 78 Morfa Road, Swansea, SA1 2EN, United Kingdom Phone: +441792 455 175 Fax: +441792 455 176 Website: www.zetaalarmsystems.com Email: info@zetaalarmsystems.com Issue 1 / Rev.1...
  • Page 2 User Guide of ZT-30P Issue 1 / Rev.1...
  • Page 3: Table Of Contents

    User Guide of ZT-30P <User Guide of ZT-30P> TABLE OF CONTENTS <User Guide of ZT-30P> ……....................3 Unpack & Checking Contents ………………………………………………………………………………..……4 DIP Switch Settings (If Required)…………………………………………………………………………………5 Install………………………………………………………………………………………………………………………….6 Operation……………………………………………………………………………………………………………………7 Operation Technical Specification……………………………………………………………………………….8 LIST OF FIGURES Figure 1. Product Contents & Outline Indication ............. 4 Figure 2.
  • Page 4: Unpack & Checking Contents

    User Guide of ZT-30P Unpack & Checking Contents - Unpack the delivered pack and check the following contents. Figure 1. Product Contents & Outline Indication Issue 1 / Rev.1...
  • Page 5: Dip Switch Settings (If Required)

    User Guide of ZT-30P DIP Switch Settings (If necessary) 1). After removing the Sunshade, separate TOP Cover & Base cover and change the Setting of the DIP Switch. Figure 2. Change of DIP Switch Setting 2). After completing the change of DIP Switch Setting, combine the TOP Cover and BASE Cover by screwing together.
  • Page 6: Install

    User Guide of ZT-30P Installation 1). Shown Fig.3, after screwing Top / Base Covers & Sunshade, place the detector in its designated locations on the wall and secure it with the provided three (3) fasteners through three (3) holes of detector mounting bracket.
  • Page 7: Operation

    User Guide of ZT-30P The Detector is now correctly located, aligned and ready to be connected to the system. Operation Once powered up, the detector will begin appr. 20 sec start-up routine. During this time, all three (3) LED indicators will be blinking. Once the start-up procedure has finished and no faults are present, the detector will begin normal operation (Green LED will remain on).
  • Page 8: Operation Technical Specification

    User Guide of ZT-30P Table 2. DIP Switch Settings DIP Switch Position No. Mode Selections Sensitivity Range (1) OFF-OFF(00) : Highest OFF-ON(01) : High ON-OFF(10) : Medium <default> ON-ON(11) : Low Alarm Delay Time (2) OFF-OFF(00) : 1 Sec OFF-ON(01) : 3 Sec ON-OFF : 7 Sec <default>...
  • Page 9: Figure 4. Typical 4-Wiring Relay Contact Outputs

    User Guide of ZT-30P Notes: 1. ( ): denotes an example of optional colour wirings. Issue 1 / Rev.1...
  • Page 10 User Guide of ZT-30P Techncial Specification Model ZT-30P 47-156 Part Number Spectrum Response UV/IR (Dual Bands) Fuel Distance Spectrum Response n-Heptane (at highest sensitivity setting for Gasoline 0.1m pan fire) Diesel LPG* Ethanol Methane** *0.5m high/0.2m width plume fire, **30” plume fire...
  • Page 11 User Guide of ZT-30P Materials Heavy duty copper free aluminium with white powder coating Mounting (Tilt Mount) Heavy duty copper free aluminium with white powder coating Detector 63(D) x 110 (L) mm Dimensions Weight Detector & Mounting Bracket (Aluminium): 0.3kg...

Table of Contents