A control can be used with the Ultra-Aire 70H. The Ultra-Aire 70H features a built-in dehumidistat control as well
as the ability to wire a remote mounted control to the unit. If the Ultra-Aire 70H is located outside of the area
where humidity control is desired, consider using a remote wired humidity controller that is located in the area
where humidity control is desired. If using the built-in dehumidistat to control the unit, locate the control in an
area where it can accurately sense the humidity of the area where humidity control is desired.
If the Ultra-Aire 70H is located in the area where humidity control is desired, consider using the built-in control.
Adjust the humidity control so that the unit maintains the desired level of humidity.
CAUTION!
WHEN USING A REMOTE WIRED DEHUMIDISTAT, BE SURE THE BUILT-IN DEHUMIDISTAT IS SET
TO THE OFF POSITION BY TURNING IT COUNTERCLOKWISE UNTIL IT STOPS. FAILURE TO DO
SO MAY CAUSE THE UNIT TO SENSE THE HUMIDITY FROM THE WRONG AREA.
Ultra-Aire offers the DEH 3000 proprietary control. The DEH 3000 allows homeowners to monitor and control
relative humidity and proper ventilation levels in their home. This control is also available with a remote
sensing option.
Note: The DEH 3000 is sold seperately and can be purchased online or through your local dealer. Other
thermostats are compatible with the Ultra-Aire 70H.
Ultra-Aire DEH 3000 Digital Control
• Central Fan Integration – Operates HVAC
fan with dehumidifier operation.
• A/C Sensor – Automatically activates or
deactivates the dehumidifier when the air
conditioner runs.
• High Temperature Cut-Out – Disables
dehumidifier operations if household
temperature reaches the cut-out setpoint.
• Dry Out Cycle Timer – Automatic fan
cycling to ensure dry and clean coils.
• Auto Reboot – Resumes operation with
prior settings in the event of power failure.
Wiring Controls
CAUTION!
DO NOT ALLOW THE YELLOW LEAD FROM THE ULTRA-AIRE 70H TO CONTACT THE RED
LEAD OR THE WHITE LEAD FROM THE ULTRA-AIRE 70H OR DAMAGE TO THE TRANSFORMERS
WILL RESULT.
DO NOT CONNECT THE WHITE WIRE TO THE CONTROL IF THE OPTIONAL DAMPER IS NOT
USED OR DAMAGE TO THE TRANSFORMER WILL RESULT.
Control Connections
The control and the control wires leaving the Ultra-Aire 70H are numbered and color-coded to prevent
confusion. Depending on the control, some of the wires leaving the Ultra-Aire 70H may not be used. For
safety, the unconnected wires should be covered with wire nuts. Be sure to consult the electrical schematic
in this manual or inside the access panel of the Ultra-Aire 70H before making control connections.
www.Ultra-Aire.com | 1-800-533-7533
See DEH 3000 manual for detailed instructions.