Download Print this page

Ice Machine; Cleaning And Sanitizing - Hoshizaki KM-340MAH Manual

Cleaning & sanitizing
Hide thumbs Also See for KM-340MAH:

Advertisement

Ice Machine

The ice maker must be cleaned & sanitized at least once a year.
Cleaning Prep:
Remove the Front Panel, move the control switch to OFF.
R
1
A
After 3 min., move the switch to ICE, then replace the panel.
A
After 3 min., remove the Front Panel, move the switch to OFF.
2
Remove all ice from the ice storage bin and/or dispenser
R
3
WARNING! IF ON DISPENSER, turn off the dispenser power
supply after dispensing all the leftover ice.
Cleaning:
Base
Cover
R
Remove the Base Cover, disconnect the Pump Tubing. After the water tank has
4
drained, reconnect Pump Tubing. Do not replace the base cover at this time.
d
R
Refill water tank by moving the control switch to ICE,
5
re
replace the Front Panel. After 3 minutes, remove the
Front Panel, then move the control switch to OFF.
R
Remove the Front Insulation Panel. Pour 14 fl.oz
6
(4
(414 ml) of Hoshizaki Scale Away into the water
tank. Replace the Front Insulation Panel. Turn the
cleaning valve left until completely vertical (open).
NOTICE! AVOID EXCESSIVE FOAMING, wait
1 minute before next step.
M
Move the control switch to WASH, replace Front
7
Panel.
P
#51001 | 7.22.2016
Page 2
Cleaning & Sanitizing
continued on the back...
Tech Support: 1.800.233.1940
3
min
.
3
min.
Front View of
Ice Maker
3
min.
OPEN
KM-340MAH, MWH
KM-515MAH, MWH, MRH
KM-600MAH
KM-650MAH, MWH, MRH
KM-901MAH, MWH, MRH/3
WARNING!
DO NOT leave icemaker
unattended when panels are off
AMMONIA
Cleaners
Sanitizing:
Fill the water tank
CLOSE
the cleaning valve
Move control switch to ICE,
replace the front panel
After 3 minutes, remove the
front panel
Move control switch to OFF
Remove the front insulation
panel
Pour .78 fl. oz (23 ml) of
chlorine bleach* into the
water tank
Replace the front insulation
panel
OPEN
the cleaning valve
* Use bleach without additives.
Additives cause excessive foaming, and
reduces effectiveness of the cleaning.
Wait 1 minute to avoid
excessive foaming
Move control switch to WASH,
replace the front panel
After 45 minutes, remove
the front panel
Move control switch to OFF
Disconnect the pump tubing
After the water tank has
drained, reconnect the pump
tubing
Page 1
14
15
16
17
g
18

Advertisement

loading