Installation; Optional Parts; Installation Parts - Toshiba RAS-10SA-E Service Manual

Split wall type
Hide thumbs Also See for RAS-10SA-E:
Table of Contents

Advertisement

8-3. Installation

8-3-1. Optional Parts

Part
Parts name
code
Refrigerant piping
A
Liquid side : ø6.35 mm
Gas side
: ø9.52 mm
Pipe insulating material
B
(polyethylene foam, 6 mm thick)
C
Putty, PVC tapes
<Anchor bolt arrangement of outdoor unit>

8-3-2. Installation Parts

Part
Name of parts
No.
Q'ty
1
Installation plate x 1
2
Wireless remote control x 1
3
Clip anchor x 6
4
Remote control holder x 1
Others
Name
Installation manual
Owner's manual
Q'ty
Each
one
1
Each
• Secure the outdoor unit with the anchor bolts if the
one
• Use ø8 or ø10 anchor bolts.
Part
Name of parts
No.
Q'ty
5
Shield pipe x 1
6
Pan head wood screw
ø3.1 x 16l x 2
7
Batteries x 2
8
Mounting screw ø4 x 25l x 6
This model is not equipped with an extension drain
hose.
Option : For the extension drain hose, use an optionally
available RB-821SW or commercially available one.
– 21 –
600mm
Air inlet
Air outlet
Fig 8-3-1 Air outlet
unit is likely to be exposed to a strong wind.
Part
No.
9
Deodorizing filter x 1
10
Purifying filter x 1
11
Filter frame x 2
Name of parts
Q'ty

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10sk-eRas-10saxRas-10skx

Table of Contents