8-2. Installation Diagram of Indoor and Outdoor Units

For installation of the indoor unit, use the paper pattern on the back.
Front cabinet
Front panel
11
Filter
frame
9 Deodorizing
filter
10 Purifying
filter
Before install the wireless
remote control
• With the remote control cover
open, load the batteries
supplied correctly, observing
their polarity.
2 Wireless remote control
7
Batteries
Cover
3 Clip anchor
Clip anchor
Hook
Hook
6 Pan head
wood screw
4 Remote control
holder
2 Wireless
remote
control
Electric parts
cover
Loop the connective cable
(about 100 mm in diameter
and 300~350 mm long).
Hook
1 Installation
plate
8 Mounting screw
5 Shield pipe
Extension
drain hose
(Option:
RB-821SW)
– 20 –
For the rear and left piping
Wall
Insert the remote control holder
cushion between the indoor
unit and wall, and lift indoor
unit to make work easier.
Do not allow the drain hose to
get slack.
Cut the piping hole
sloped slightly
Make sure to run the drain
hose sloped downward.
The auxiliary piping can be
connected the left, rear left,
rear, right or bottom.
Right
Rear
Rear left
Bottom
Insulation of refrigerant pipes
insulates the pipes separately,
not together.
6 mm thick heat resisting
polyethylene foam
Left

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-10sk-eRas-10saxRas-10skx