GB
simply rectified by connecting the appliance
to the mains supply via a socket without a
safety cut-out, so that the moisture can be
driven out of the element. The drying time
can vary from a few hours to a few days. As
a preventive measure the unit should occa-
sionally be run for a short time when it is not
being used for extended periods of time.
Safety
• Keep the areas around the air intake and
exhaust grilles free from possible obstruc-
tions!
• During operation the surfaces of the unit
are hot!
• The unit must not be fully or partially
covered with textiles, or similar materials,
as overheating can result in a fire risk!
ADR E
Type
Output
stages
[kW]
ADR210E
0/ /6/9
ADR215E
0/ /8/12
ADR220E
0/ /12/18 1350/2030/2700
ADR310E
0/ /6/9
ADR315E
0/ /8/12
ADR320E
0/ /12/18 1750/2630/3500
) Dt = Temperature rise of passing air at maximum heat output and low/medium/high airflow.
*
1
) Conditions: Distance to unit: 5 m. Direction factor: 2. Equivalent absorption area: 200 m 2 .
*
2
Protection class ADR E: (IP23).
1
Dt*
Airflow
1
[m
/h]
[
C]
3
°
700/1050/1400
38/25/19
1050/1580/2100
33/22/17
39/26/19
950/1430/1900
28/19/14
1250/1880/2500
29/19/14
31/20/15
ADR E
Sound
Voltage/am-
level*
perage
2
[dB(A)]
(control)
40/50/57
230V~/1,6 A
43/53/60
230V~/2,3 A
44/53/60
230V~/3,1 A
44/54/61
230V~/2,2 A
43/53/60
230V~/2,3 A
45/55/62
230V~/3,9 A
Voltage/
Weight
amperage
(heat)
[kg]
400V3~/13 A
39
400V3~/17,5 A
56
400V3~/26 A
77
400V3~/13 A
44
400V3~/17,5 A
56
400V3~/26 A
81