Download Print this page
Frico ADCS Manual

Frico ADCS Manual

Ad corinte w

Advertisement

Quick Links

SE
GB
...16
NL
ES
...34
NO
...19
...22
PL
...37
...40
AD Corinte W - ADCS
FR
RU
...25
FI
IT
...43
DE
...28
...31
DK
...46
...49

Advertisement

loading

Summary of Contents for Frico ADCS

  • Page 1 AD Corinte W - ADCS ...16 ...19 ...22 ...25 ...28 ...31 ...34 ...37 ...40 ...43 ...46 ...49...
  • Page 2 AD Corinte W - ADCS...
  • Page 3 AD Corinte W - ADCS...
  • Page 4 AD Corinte W - ADCS Fig 4...
  • Page 5 AD Corinte W - ADCS Fig 5...
  • Page 6 AD Corinte W - ADCS 1700/2200 1670/2170 Left connection Wall Right connection Cu ø22 Cu ø22 Fig 6a Min 180 mm Min 180 mm Fig 6b...
  • Page 7 AD Corinte W - ADCS Fig 6c Fig 6d Fig 7...
  • Page 8 AD Corinte W - ADCS ADCEH Ø8 2 alternatives for securing at the top.* Ø12 (2x) Ø8 for securing at the air curtain.* SE / NO / FR / RU / DE / NL / ES / PL / FI / IT / DK ) 2 alt.
  • Page 9 AD Corinte W - ADCS ADCS - SIRe Fig 8 SIRe...
  • Page 10 AD Corinte W - ADCS SIRe SIReB SIReAC SIReAA SIReRTX 70x33x23 mm SIReUR 114x70x50 mm SIReWTA SIReB SIReUR SIReCJ4 SIReCJ6 SIReCC603 SIReWTA SIReCC605 SIReCC610 10 m SIReCC615 15 m SIReCC640 40 m SIReAC/SIReAA SIReCC403 SIReCJ4/SIReCJ6 SIReCC405 SIReCC410 10 m SIReCC415...
  • Page 11: Internal Wiring Diagram

    AD Corinte W - ADCS Wiring diagrams Internal wiring diagram ADCS W 230V~ Internal Motor sensor protection 230V Yellow 230V 200V Orange 200V 170V 170V 145V Brown 145V 120V Black 120V 100V Green 100V Blue Blue Black 230V~...
  • Page 12 AD Corinte W - ADCS Wiring diagrams SIRe B Basic SIReUB1 SD230 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) L=1,5m SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY...
  • Page 13 AD Corinte W - ADCS ADCS WH Supply water temperature: 110 °C Water temperature: 110/80 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position...
  • Page 14 AD Corinte W - ADCS ADCS WL Supply water temperature: 80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output* Outlet Water Pressure position...
  • Page 15: Technical Specifications

    AD Corinte W - ADCS Technical specifications Water heat - ADCS WH, coil for high temperature water (≥80 °C) (IP20) ∆t* Type Output* Airflow* Water Sound Motor Voltage Amperage Length Weight volume level* motor motor [kW] [°C] [dB(A)] [mm] [kg] ADCS17WH*¹...
  • Page 16 Make sure that the flat Application bar is not bent when fixing. The AD Corinte W - ADCS air curtain is 6. Secure the top with an angle bracket or supplied with a water coil and is intended...
  • Page 17 AD Corinte W - ADCS Horizontal mounting on the ceiling the air curtain pipes. The flexible hoses are 1. Mount pendulums or similar (not included connected to the system beneath the floor. on delivery) on the ceiling with c-c distance Note! At connection from below, avoid placing according to Fig.
  • Page 18 AD Corinte W - ADCS 3. Carefully wipe the fins of the heating coil with a wet cloth. 4. Remount the air intake grllle. 5. Connect the power. Filter cassettes, that the unit may be equipped with, cannot be cleaned but need to be changed when they are soiled or when the airflow is reduced.