Block and Schematic Diagrams
Schematic Diagram Notes
Components identified by
When replacing any of these components, use only manufacture's specified parts.
Notes:
1. Resistor
All resistors are cabon 1/4W resistor, unless marked as follows:
Unit of resistance is OHM [ Ω] (K=1,000, M=1,000,000).
2. Capacitor
All capacitors are ceramic 50V capacitor, unless marked as follows:
Unit of capacitance is F, unless otherwise noted.
M
m
3. Coil
Unit of inductance is H, unless otherwise noted.
4. Test Point
5. Earth Symbol
6. Voltage Measurement
Voltage is measured by a DC voltmeter.
Conditions of the measurement are the following:
7. Number in red circle indicates waveform nember.
(See waveform pattern table.)
8. When arrow mark (
9. Indicates the major signal flow.
10. This schematic diagram is the latest at the time of printing and subject to change without
notice.
Remarks:
1. The Power Circuit contains a circuit area which uses a separate power supply to isolate the
earth connection.
The circuit is defined by HOT and COLD indications in the schematic diagram. Take the
follwing precautions.
All circuits, except the Power Circuit, are cold.
Precautions
2. Following diodes are interchangeable.
MA150- MA162 (Replacement part)
Schematic Diagram Notes
Important Safety Notice
mark have special characteristics important for safety.
: Nonflammable
: Solid
: Wire Wound
: Temperature Compensation
: Polyester
: Metalized Polyester
: Polypropylene
: Test Point position
: Chassis Earth (Cold)
Power Source ................................................... AC220-240V, 50/60Hz
Receiving Signal ............................................... Colour Bar signal (RF)
All customer's controls ...................................... Maximum positions
) is found, connection is easily found from the direction of arrow
a. Do not touch the hot part or the hot and cold parts at the same time or you may
be shocked.
b. Do not short- circuit the hot and cold circuits or a fuse may blow and parts may
break.
c. Do not connect an instrument, such as an oscilloscope, to the hot and cold
circuits simultaneously or a fuse may blow.
Connect the earth of instruments to the earth connection of the circuit being
measured.
d. Make sure to disconnect the power plug before removing the chassis.
: Metal Oxide
: Metal Film
: Fuse:
: Electrolytic
NP
: Bipolar
: Dipped Tantalum
T
: Z-Type
Z
: Line Earth (Hot)
: Video
Audio
– 47 –