Commercial reference: sales@seneca.it It is a registered International trademark ® 2010 All rights reserved This document is property of SENECA srl. Duplication and reproduction of its are forbidden (t hough partial ), if not authorized. Contents of present documentation refers to products and technologies described in it. Though we strive for reach perfection continually , all technical data contained in this document may be modified or added due to technical and commercial needs;...
2. PRELIMINARY WARNINGS Before carrying out any operation it’s mandatory to read all the content of this user Manual . Only electrical-skilled technicians can use the module described in this user Manual. Only the M anufacturer is authorized to repair the module or to replace damaged components.
Millivoltmeter-type Scale range is configurable between: -10 mV to 80 mV. Input impedance: > 5 M Errors related to Accuracy Thermal Linearity error EMI measuring range stability Voltage or current- 0.1% 0.01%/°K 0.05% <1% (2) type input TC-type input: J, K, 0.1% 0.01%/°K 0.2°C...
It is forbidden to obstruct the module ventilation openings. It is forbidden to install the module near heat-emitting devices. Power off the module before connecting: RS232 serial interface, RS485 serial interface, input, output. 5.2 RS485 AND RS232 SERIAL INTERFACE The module is designed to data interchange according to the ModBUS protocol rules, implemented by RS232 serial interface and RS485 serial interface The RS232 (with unchangeable parameters)
It’s possible to configure the module by two types of parameters: communication parameters and setting parameters. It’s possible to know the module in details (with RS485 registers) to keep visiting the internet site www.seneca.it 6.1 SETTING PARAMETERS The setting parameters are: input type, input filter, input start/end scale, output type, output start/end scale, output limiter, electric-line frequency rejection, cold-junction compensation (for TC-type input), burn (for RTD or TC-type input), PID parameters.
It’s possible to download these software s to keep visiting the Internet site www.seneca.it. 6.3 DIP-SWITCH TABLES Power off the module before configuring it by Dip-Switches to avoid electrostatic discharges. In the following tables: box without circle means Dip-Switch=0 (OFF state); box with circle means Dip-Switch=1 (ON state).
RS232 2400( unchangeable 1( unchangeable ) RS485 38400 To know the default configuration for the setting parameters, see User Manual (www.seneca.it). 7. MOST IMPORTANT RS485 REGISTERS Name Description Address Address Set Point Input set-point for the PID regulation: [%] with...