Download Print this page
Sealey Power PRODUCTS SAC3103B Instructions Manual

Sealey Power PRODUCTS SAC3103B Instructions Manual

50/100ltr belt drive 3.0hp with front control panel

Advertisement

Quick Links

thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE REAd THESE iNSTRUCTiONS CAREFULLY. NOTE THE SAFE OPERATiONAL REQUiREMENTS, WARNiNGS & CAUTiONS. USE
THE PROdUCT CORRECTLY ANd WiTH CARE FOR THE PURPOSE FOR WHiCH iT iS iNTENdEd. FAiLURE TO dO SO MAY CAUSE dAMAGE OR
PERSONAL iNJURY ANd WiLL iNvALidATE THE WARRANTY. PLEASE KEEP iNSTRUCTiONS SAFE FOR FUTURE USE.
1. SAFETY iNSTRUCTiONS
1.1.
ELECTRiCAL SAFETY
 WARNiNG! It is the responsibility of the owner and the operator to
read, understand and comply with the following: You must check all
electrical products, before use, to ensure that they are safe. You must
inspect power cables, plugs, sockets and any other connectors for wear
or damage. You must ensure that the risk of electric shock is minimised
by the installation of appropriate safety devices. A residual current
circuit Breaker (rccB) should be incorporated in the main distribution
board. We also recommend that a residual current device (rcd) is
used. It is particularly important to use an rcd with portable products
that are plugged into a supply which is not protected by an rccB. If in
any doubt consult a qualified electrician. You may obtain a residual
current device by contacting your sealey dealer. You must also read
and understand the following instructions concerning electrical safety.
1.1.1. the Electricity at Work Act 1989 requires that all portable
electrical appliances, if used on business premises, are tested
by a qualified electrician, using a Portable Appliance tester
(PAt), at least once a year.
1.1.2. the Health & Safety at Work Act 1974 makes owners of
electrical appliances responsible for the safe condition of those
appliances and the safety of the appliance operators. if in any
doubt about electrical safety, contact a qualified electrician.
1.1.3. ensure that the insulation on all cables and on the appliance is
safe before connecting it to the power supply. see 1.1.1. and
1.1.2. and use a Portable Appliance tester.
1.1.4. ensure that cables are always protected against short circuit
and overload.
1.1.5. regularly inspect power supply cables and plugs for wear or
damage and check all connections to ensure that none is loose.
1.1.6. important: ensure that the voltage marked on the appliance
matches the power supply to be used and that the plug is fitted
with the correct fuse - see fuse rating below.
1.1.7. dO NOT pull or carry the appliance by the power cable.
1.1.8. dO NOT pull the plug from the socket by the cable.
1.1.9. dO NOT use worn or damaged cables, plugs or connectors.
Immediately have any faulty item repaired or replaced by a
qualified electrician.
1.1.10. Model Nos SAC3503B and SAC3103B are supplied with a
flying lead without a plug. Jack Sealey Limited recommend
a 16 amp protected supply. When connecting to a 16 amp
protected supply, contact a qualified electrician, to ensure
connection to a suitably rated supply.
*Provided a good 230V supply is available and the lead
length is not increased from that supplied, the compressor
may operate from a 13 amp supply. This very much
depends upon the quality of your power supply.
1.2
Wiring a BS 1363/A UK 3 Pin Plug
if in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth
terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that
all wires have been correctly connected, that the cable outer
insulation extends beyond the cable restraint and that the
restraint is tight.
double insulated products, which are always marked with this
symbol
, are fitted with live (brown) and neutral (blue) wires
only. to rewire, connect the wires as indicated in diagram.
dO NOT connect either wire to the earth terminal.
© Jack sealey limited 2013
InstructIons for:
COMPRESSOR 50/100ltr BELT dRivE
3.0hp WiTH FRONT CONTROL PANEL.
model nos:
We recommend that you discuss the installation of an
industrial round pin plug and socket with your electrician.
iMPORTANT! the use of extension leads to connect these
compressors to the mains is not recommended as the resulting
voltage drop reduces motor, and therefore pump performance.
see 1.1.10 for power supply options.
decompression
tube from switch
non return valve
to receiver
Hose reel tidy
Original Language Version
SAC3503B/SAC3103B
RECOMMENdEd
FUSE RATiNG:
*13 AMP
from
pump
sAc3503B/sAc3103B
Issue no: 1 - 01/06/13
fig.1

Advertisement

loading

Summary of Contents for Sealey Power PRODUCTS SAC3103B

  • Page 1 SAC3503B/SAC3103B model nos: thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE REAd THESE iNSTRUCTiONS CAREFULLY. NOTE THE SAFE OPERATiONAL REQUiREMENTS, WARNiNGS & CAUTiONS. USE THE PROdUCT CORRECTLY ANd WiTH CARE FOR THE PURPOSE FOR WHiCH iT iS iNTENdEd.
  • Page 2: General Safety

    NOT subject the tank to impact, vibration or heat. fully dO NOT allow contact with abrasives or corrosives. inflated drain condensation from tank daily. 1.5bar chocks Wall 1000mm nominal Original Language Version © Jack sealey limited 2013 sAc3503B/sAc3103B Issue no: 1 - 01/06/13...
  • Page 3: Operation

    (fully clockwise). make sure that the pressure in the tank rises and that the compressor stops automatically when the maximum pressure value is reached. this value is written on switch/motor cable Original Language Version sAc3503B/sAc3103B Issue no: 1 - 01/06/13 © Jack sealey limited 2013...
  • Page 4: Maintenance

    +5°c to +25°c. of receiver, ensure fig.6 seAleY cPo or equivalent sAe 40 compressor oil. room shut on start up (4.3) temperature below +5°c: sAe 20 compressor oil. drain daily (5.3.) iMPORTANT WARNiNG - Air contaminants taken into the 5.4.
  • Page 5: Troubleshooting

    See fig.1 for location and section 6.2 Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500. Environmental Protection. recycle unwanted materials instead of disposing of them as waste.
  • Page 6 Original Language Version sAc3503B/sAc3103B Issue no: 1 - 01/06/13 © Jack sealey limited 2013...

This manual is also suitable for:

Power products sac3503b