Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND
CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
Familiarise yourself with the application and limitations of the
compressor.
Ensure that the compressor is in good order and condition before
use. If in any doubt do not use the compressor and contact a
service agent.
 WARNING! Compressor must only be serviced by an
authorised agent. DO NOT tamper with, or attempt to adjust
the pressure switch or the safety valve.
Before moving or maintaining the compressor ensure that the air
tank pressure has been vented.
Only use recommended attachments and parts. Unapproved
items may be dangerous and will invalidate the warranty.
Read the instructions for any accessory used with the
compressor. Ensure that the safe working pressure of any air
appliance used, exceeds the output pressure of the compressor.
If using a spray gun, check that the area selected for spraying is
provided with an air change system or adequate ventilation.
Ensure that the air supply valve is turned off before disconnecting
the air supply hose.
Use the compressor in a well ventilated area and ensure it is
placed on a firm surface. Remember that the compressor
engine produces harmful exhaust fumes.
Keep tools and other items away from the compressor when it is
in use, and keep work area clean.
Ensure that air hoses are not tangled, twisted or pinched.
Keep children and unauthorised persons away from the work area.
DO NOT dis-assemble the compressor for any reason if you are not
qualified to do so. The unit must be checked by qualified personnel
only.
DO NOT operate the compressor within the vicinity of flammable
liquids, gases or solids.
DO NOT touch compressor cylinder, cylinder head or pipe from
head to tank as these may be hot and will remain so for some
time after shutdown.
DO NOT operate the compressor without all safety guards in
place.
DO NOT attempt to move the compressor by pulling the air tool
hose.
DO NOT use the compressor for a task for which it is not
designed.
DO NOT deface the certification plate attached to the compressor
tank.
DANGER! DO NOT direct the output jet of air towards people
or animals.
DO NOT operate the compressor without an air filter.
InSTRUcTIOnS FOR:
COMPRESSOR 150LTR BELT
DRIVE PETROL ENGINE 6.5HP
MOdEl no:
DO NOT allow anyone to operate the compressor unless they
have received full instructions.
For safety instructions relative to the maintenance and use of the
petrol engine - refer to the engine manufacturer's handbook
supplied.
DO NOT check the ignition system by removing the spark plug or
spark plug lead. Use specific tester or contact service agent.
WARNING! DO NOT touch the spark plug or plug lead whilst
the engine is running - severe, potentially fatal, electric
shock may result.
Ensure that engine fuel is stored in an approved container. For
long term storage ensure that the fuel tank is drained and that
the compressor is adequately protected.
DO NOT smoke or have any naked flames nearby whilst
re-fuelling.
DO NOT leave the compressor operating unattended.
DO NOT remove the fuel cap, or try to refuel whilst the engine is
running. Stop the engine and allow it to cool for two minutes
before attempting to refuel.
DO NOT refuel in a closed or poorly ventilated environment as
there is a danger of explosion or fire. Refuel outdoors.
DO NOT operate the compressor if there is a fuel leak. Move the
unit to a safe area, where there is no risk of ignition, until the leak
has been rectified and the machine is dry.
DO NOT start the engine if there are any flammable materials
near the exhaust system or in the path of the exhaust gases.
DO NOT block the engine ventilation grilles.
DO NOT cover the compressor or restrict air flow around the
machine whilst it is operating.
WARNING! The air tank is a pressure vessel and the
following safety measures apply:
DO NOT tamper with the safety valve and DO NOT modify or
alter the tank in any way and DO NOT strap anything to the tank.
DO NOT subject the tank to impacts, vibration or to heat and
DO NOT allow contact with abrasive or corrosive materials.
DO drain condensation from tank daily and inspect inside
walls for corrosion every 12 months.
The tank shell must not fall below the certified thickness at
any point.
When not in use, store the compressor carefully in a safe, dry,
childproof location.
 When the compressor is not in use, it should be switched
off and the air drained from the tank.
Original Language Version
SA1565
SA1565
Issue: 2 - 20/02/12

Advertisement

loading

Summary of Contents for Sealey Power PRODUCTS SA1565

  • Page 1 SA1565 MOdEl no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2: Introduction & Specification

    Note: a) If the relief valve does not cut in and out, but is 2. INTRODUCTION & SPECIFICATION continuously closed whilst using an air appliance, the Static compressor with Honda GX200 6.5hp power unit coupled to capacity of the compressor may be too small for the heavy-duty, two stage twin piston, cast iron pump.
  • Page 3: Maintenance

    5. MAINTENANCE In order to keep the compressor in good working condition, periodic maintenance is essential. IMPORTANT! Failure to carry out maintenance tasks may invalidate the warranty on your compressor. WARNING! Service and maintenance must be performed by an authorised agent. DO NOT tamper with, or attempt to adjust, the pressure switch or safety valve.
  • Page 4: Troubleshooting

    When the product is no longer required, it must be disposed of in an environmentally protective way. Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500.