10. Module Operation After Power Supply Recovery
The module operation after power supply recovery depends on the duration of the power failure.
If the duration of the power failure is shorter than the set Blackout notification delay, the
module resumes operation and does not send any messages. If this delay has elapsed and the
module has already sent a power failure notification but has not yet been shut down, the module
resumes operation and informs the authorized users by an SMS message. If the module has
been shut down in the event of the power failure (after Switch off notification delay has elapsed
or because the built-in battery voltage has dropped below the specified limit), the standard
power-on process of the module is initiated when the power supply is restored. After
initialization, the authorized users are notified by a ring.
11. Operation and Maintenance of the G2S-T Module
The G2S-T module may only be used under the conditions described in this manual. Otherwise,
no warranty will be provided. The manufacturer shall not be liable for any damages caused by
the use of the device other than as stated in the manual. In case of malfunction or damage, the
device must be switched off and disconnected from the mains. Under no circumstances, user
can dismantle or attempt to repair the module. Any repairs may only be carried out by the
manufacturer or an organization authorized by the manufacturer. The G2S-T module does not
require any special maintenance during operation. It must be protected from moisture, water,
limit temperatures and mechanical damage. In addition, children should not be allowed to
handle the device. Any dirt and dust should be carefully removed from the module surface with
a soft cloth. If necessary, a damp cloth with a non-abrasive cleaning agent can be used. In any
case, prevent moisture or any other contamination from entering the module, connectors and
SIM card slot!
12. Specifications
Power supply:
Maximum input current
Dimensions (W x D x H):
Module weight:
Operating temperature:
Storage temperature:
GSM bands:
Compatible GSM network:
SIM card format:
Max. relay contact load:
USB port:
12V DC from the mains power supply adapter
0.5A at 12V supply voltage
112 x 67 x 28 mm
160g
0°C to +40°C
-25°C to +60°C
GSM 900 and 1800 MHz
according to the SIM card used
Mini-SIM (2FF)
24V/2A
Mini-B
- 9 -