MODELS AVAILABLE AND ELECTRICAL DATA - Table 8
Model
H_GHCU
H_GHEU
H_GHTU
H_GHWU
H_GHGU
H_GHHU
H_GHCU*
H_GHEU*
H_GHTU
H_GHWU
H_GHGU
HBGH
H_GHHU
HCGH
H_GHCU*
HSGH
H_GHEU*
HTGH
H_GHTU
H_GHWU
H_GHGU
H_GHHU
H_GHCU*
H_GHEU*
H_GHTU*
H_GHWU
H_GHGU
H_GHHU
H_HHCU*
H_HHEU*
H_HHTU*
H_HHWU*
H_HHGU*
H_HHHU
H_HHCU*
H_HHEU*
H_HHTU*
H_HHWU*
H_HHGU*
HBHH
H_HHHU*
HCHH
HSHH
H_HHCU*
HTHH
H_HHEU*
H_HHTU*
H_HHWU*
H_HHGU*
H_HHHU*
H_HHCU*
H_HHEU*
H_HHTU*
H_HHWU*
H_HHGU*
H_HHHU*
www.carnes.com
Max
Lb/Hr
Voltage
Phase
50
208
3
50
230
3
50
380
3
50
415
3
50
460
3
50
575
3
60
208
3
60
230
3
60
380
3
60
415
3
60
460
3
60
575
3
80
208
3
80
230
3
80
380
3
80
415
3
80
460
3
80
575
3
100
208
3
100
230
3
100
380
3
100
415
3
100
460
3
100
575
3
125
208
3
125
230
3
125
380
3
125
415
3
125
460
3
125
575
3
150
208
3
150
230
3
150
380
3
150
415
3
150
460
3
150
575
3
175
208
3
175
230
3
175
380
3
175
415
3
175
460
3
175
575
3
200
208
3
200
230
3
200
380
3
200
415
3
200
460
3
200
575
3
Humidifiers | Unit Availability
Optional
Line
Disc.
Cir.
kW
Amp
Size
Breaker*
17.2
47.8
80
2-35 Amp
17.2
43.2
70
1-60 Amp
17.2
26.2
40
1-40 Amp
17.2
24.0
40
1-40 Amp
17.2
21.6
35
1-30 Amp
17.2
17.3
30
1-25 Amp
20.7
57.4*
90
2-40
20.7
51.9*
80
2-40
20.7
31.4
50
1-50 Amp
20.7
28.8
45
1-45 Amp
20.7
26.0
40
1-40 Amp
20.7
20.8
35
1-30 Amp
27.5
76.5*
125
2-60
27.5
69.2*
110
2-50
27.5
41.9
70
1-60 Amp
27.5
38.4
60
1-60 Amp
27.5
34.6
60
1-50 Amp
27.5
27.7
45
1-40 Amp
34.4
95.6*
150
2-60
34.4
86.4*
150
2-60
34.4
52.3*
110
2-50
34.4
47.9
80
2-40 Amp
34.4
43.3
70
1-60 Amp
34.4
34.6
60
1-50 Amp
43
119.5*
200
4-40
43
108*
175
4-40
43
65.3*
100
2-50
43
59.8*
90
2-45
43
54.0*
90
2-40
43
43.2
70
2-30 Amp
51.7
143.5*
225
4-50
51.7
129.7*
200
4-50
51.7
78.6*
125
2-60
51.7
71.9*
110
2-60
51.7
64.8*
100
2-50
51.7
51.9*
80
2-35
60.3
167.3*
300
4-60
60.3
151.3*
250
4-60
60.3
91.6*
150
4-35
60.3
83.9*
150
2-60
60.3
75.6*
125
2-60
60.3
60.5*
100
2-50
68.9
191.2*
300
4-60
68.9
172.9*
300
4-60
68.9
104.7*
175
4-40
68.9
95.9*
150
4-35
68.9
86.4*
150
2-60
68.9
69.2*
110
2-50
* = Circuit Breaker is REQUIRED per NEC 48 amp guidelines.
Steam
Cyl Wire
Cylinder
Current
C62
23.9
C62
21.6
C65
26.2
C65
24
C65
21.6
C65
17.3
Amp*
C62
28.7
Amp*
C62
26
C65
31.4
C65
28.8
C65
26
C65
20.8
Amp*
C62
38.2
Amp*
C62
34.6
C12
21
C12
19.2
C12
17.3
C12
13.9
Amp*
C62
47.8
Amp*
C62
43.2
Amp*
C12
34.2
C12
24
C12
21.7
C12
17.3
Amp*
C62 (2)
29.8
Amp*
C62 (2)
27
Amp*
C12 (2)
16.3
Amp*
C12 (2)
15
Amp*
C12 (2)
13.5
C12 (2)
10.8
Amp*
C62 (2)
35.8
Amp*
C62 (2)
32.4
Amp*
C12 (2)
19.7
Amp*
C12 (2)
18
Amp*
C12 (2)
16.2
Amp*
C12 (2)
13
Amp*
C62 (2)
41.8
Amp*
C62 (2)
37.8
Amp*
C12 (2)
22.9
Amp*
C12 (2)
21
Amp*
C12 (2)
18.9
Amp*
C12 (2)
15.1
Amp*
C62 (2)
47.8
Amp*
C62 (2)
43.2
Amp*
C12 (2)
26.2
Amp*
C12 (2)
23.9
Amp*
C12 (2)
21.6
Amp*
C12 (2)
17.2
G-15