Download Print this page

Sealey YAJ201 Instructions page 3

Air operated jack 20tonne-single stage

Advertisement

7. MAINTENANCE
IMPORTANT: Only fully qualified personnel should attempt maintenance or repair.
WARNING! Disconnect jack from air supply before changing parts, servicing or performing any maintenance.
7.1.
When the jack is not in use, the piston rod must be in the lowest position to minimise corrosion.
7.2.
Confirm that the piston can rise to the highest position before use.
7.3.
If the air system does not have an oiler, lubricate the air pump once or twice a month with a few drops of Sealey air tool oil dripped into
the air inlet to prolong air pump life.
7.4.
After extensive use, the oil should be replaced in order to extend the life of your equipment. This procedure should be undertaken by
a hydraulic repair specialist. The capacity of the reservoir is .72ltr; only a good quality hydraulic jack oil such as Seeley Jack Oil
should be used.
7.5.
Check the piston rod periodically for signs of corrosion. Clean exposed areas with a clean oiled cloth.
IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THE MACHINE.
Air / Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK.
DO NOT return jacks to us. Please telephone us on 01284 757500 to obtain the address and phone number of your local agent. If the jack
is under guarantee please contact your dealer.
Decommissioning the jack
Should the Jack become completely unserviceable and require disposal, draw off the oil into an approved container and dispose of the jack
and the oil according to local regulations.
7. TROUBLESHOOTING
PROBLEM
Vehicle does not lift but pump is OK
Air pump does not operate.
Vehicle stops before lift is completed.
Jack lowers or does not hold vehicle
in the raised position.
Lifting is too slow
Pump continues to operate when the
air valve is closed.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling
centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires
disposal, drain off any fluids (if applicable) into approved containers and dispose of the product and the fluids according to local regulations.
Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk,
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack Sealey Limited
POSSIBLE CAUSE
1. Oil exhausted.
2. Air in hydraulic system.
3. Defective suction or delivery valves.
4. Defective packing or 0-ring.
5. Poor oil quality.
1. Insufficient compressor power.
2. Pump oil used up.
1. Hydraulic oil is insufficient.
1. Defective suction, delivery, release or
safety valve.
2. Defective piston packing.
1. Air leakage due to worn servo-valve.
1. Air valve will not close.
Environmental Protection
email sales@sealey.co.uk or telephone 01284 757500.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
REMEDY
1. Supply oil.
2. Purge the hydraulic circuit..
3. Clean clogged valve.
4. Replace.
5. Replace oil.
1. Use a compressor larger than 3HP.
2. Dismantle the air pump and coat it with soft quality non
acid grease or lubricate air valve.
1. Supply oil.
1. Clean and adjust valve.
2. Replace packing.
1. Replace servo-valve.
1. Replace valve.
01284 757500
01284 703534
www.sealey.co.uk
sales@sealey.co.uk
YAJ201
Issue: 1 -08/12/14

Advertisement

loading