4.4.5.
For Continuity Tests if resistance is <150Ω a tone will sound.
4.5.
non contact ac voltage measurements
Warning! risk of electrocution. Before use, always test the Voltage detector on a known live circuit to verify proper operation
4.5.1.
touch the probe tip (fig. 2 item 14) to the live conductor or insert into the live side of the electrical outlet.
4.5.2.
if Ac voltage is present, the detector light will illuminate.
note!
the conductors in electrical cord sets are often twisted. for best results, rub the probe tip along a length of the cord to assure placing
the tip in close proximity to the live conductor.
note!
the detector is designed with high sensitivity. static electricity or other sources of energy may randomly trip the sensor. this is normal
operation.
4.6.
MODE BUTTON (fig.2 item 8)
to select dc/Ac Volts, oHm / diode / continuity
4.7.
DATA HOLD BUTTON(fig.2 item 5)
to freeze the lcd meter reading, press the data hold button. the data hold button is located on the left side of the meter (top button).
While data hold is active, the Hold display icon appears on the lcd. Press the data hold button again to return to normal operation.
4.8.
MAX HOLD BUTTON (fig.2 item 10)
the max. Hold position is used to measure the maximum value. the maximum measured value is updated continuously. Pressing once
again, the button will release the hold and allow a further measurement.
4.9.
RANGE BUTTON (fig.2 item 9)
When the meter is first turned on, it automatically goes into Auto Ranging. This automatically selects the best range for the
measurements being made and is generally the best mode for most measurements. for measurement situations requiring that a range
be manually selected, perform the following:
4.9.1.
Press the RANGE button. The "Auto Range" display indicator will turn off, The "Manual Range" display indicator will turn on.
4.9.2.
Press the rAnGe button to step through the available ranges until you select the range you want.
4.9.3.
Press and hold the rAnGe button for 2 seconds to exit the manual ranging mode and return to Auto ranging.
Weee regulations
dispose of this product at the end of its working life in compliance with the eu directive on Waste electrical and electronic equipment
(Weee). When the product is no longer required, it must be disposed of in an environmentally protective way. contact your local solid
waste authority for recycling information.
BatterY removal - see section 1.3
under the Waste Batteries and Accumulators regulations 2009, Jack sealey ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak's registered compliance scheme. Jack
sealey ltd Batteries Producer registration number (BPrn) is BPrn00705.
environment protection
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
note: it is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey group, Kempson Way, suffolk Business park, Bury st edmunds, suffolk. ip32 7ar
01284 757500
© Jack sealey limited
Red
Black
Black
Probe
Probe Probe
Forward test
Reverse test
fig.5
01284 703534
Original Language Version
Red
Probe
sales@sealey.co.uk
www.sealey.co.uk
tm105 issue 3 (H, 1, 3, 4, f) 05/01/18

Advertisement

loading