1.3.
BatterY installation (fig.1)
Warning! to avoid electric shock, disconnect the test leads from any source of voltage
before removing the battery cover.
1.3.1.
disconnect the test leads from the meter.
1.3.2.
open the battery cover by loosening the cover screw using a cross-head screwdriver.
1.3.3.
insert the battery into battery holder, observing the correct polarity.
1.3.4.
replace the battery cover. secure with the screw.
Warning! to avoid electric shock, do not operate the meter until the battery cover is in place
and fastened securely.
note! if the meter does not work properly, check the battery to make sure that it is still charged and that it
is properly inserted.
2.
introduction
i
High precision clamp meter. conforms with en61010-1 cAtiii 600V safety requirements for electrical
equipment for measurement, control, and laboratory use. features non-contact Ac voltage detection function
while controls are laid out to enable use with one hand. includes data/max hold functions. double moulded
housing with soft grip case and large, backlit display for ease of use even in dark areas. supplied in zipped
pouch with carry strap.
3.
specification
i
3.1.
electrical details
function
ac current
(50/60Hz)
dc voltage
ac voltage
resistance
model no:..........................tm105
Ac Voltage (Accuracy) .......200mV(±1.5%), 2V, 20V, 200V(±1.8%), 600V(±2.5%)
dc Voltage (Accuracy) .......0-200mV(±0.8%), 2V, 20V, 200V(±1.5%), 600V(±2%)
Ac current (Accuracy) ..... 2A, 20A, 200A(±2.5%), 400A(±3%)
dc current (Accuracy)......no
resistance (Accuracy) .......0-200Ω(±1%), 2kΩ, 20kΩ,200kΩ(±1.5%), 2MΩ(±2.5%), 20MΩ(±3.5%)
continuity Audible............Yes
diode test........................Yes
digits x Height..................3.5 x 14mm
low Battery indicator........Yes
Battery (supplied).............1 x 9V
Jaw opening....................32mm
information....................... Data-hold, Auto Power Off, Non-contact Voltage Detection
size..................................197 x 70 x 40mm
Weight..............................345gm
conformity........................en61010-1
for indoor use and in accordance with overvoltage category ii, Pollution degree 2. category ii includes local level, appliance, portable
equipment, etc., with transient overvoltages less than overvoltage cat. iii
© Jack sealey limited
range
2.000AAc
20.00AAc
200.0AAc
400.0 AAc
200.0 mVdc
2.000 Vdc
20.00 Vdc
200.0 Vdc
600.0 Vdc
200.0 mVAc
2.000 VAc
20.00 VAc
200.0 VAc
600.0 VAc
200.0 Ω
2.000KΩ
20.00KΩ
200.0KΩ
2.000MΩ
20.00MΩ
Original Language Version
accuracy (% of reading)
± (2.5 % + 10 digits)
± (2.5 % + 4 digits)
± (2.5 % + 4 digits)
± (3 % + 4 digits)
± (0.8% + 2 digits)
± (1.5% + 2digits)
± (2 % + 2 digits)
± (1.5% + 35 digits)
± (1.8% + 8 digits)
± (2.5% + 8 digits)
± (1.0% + 4 digits)
± (1.5% + 2 digits)
± (2.5% + 3 digits)
± (3.5% + 5 digits)
tm105 issue 3 (H, 1, 3, 4, f) 05/01/18