Bosch ACS 151 Original Instructions Manual page 12

A/c service unit
Table of Contents

Advertisement

en
12 | ACS 151 | Commissioning
Step Press
To...
key...
7
Enter
Enter the quantity of re-
frigerant to be filled.
Enter
8
Fill R134a to the internal
cylinder
4. Follow the instructions on the screen.
"
You have successfully filled R134a to the internal re-
frigerant tank.
i
Follow the same procedure every time you need to
fill R134a to the refrigerant tank.
i
To view the quantity of refrigerant, press the Enter
key from the main menu. The quantity of R134a in
the internal refrigerant tank is displayed. To return to
the main menu, press the Enter key again.
|
F 002 DG9 448
2018-02-01
Remarks
R The message
FILL QTY:
is displayed. En-
ter the quantity
of refrigerant to
be filled.
R To ensure reli-
able operation,
it is recom-
mended to use
the optimum re-
frigerant quan-
tity. The opti-
mum refrigerant
quantity for the
ACS 151 is 4 kg
- 7 kg. If the
quantity is too
less, you may
not be able to
recharge the re-
frigerant during
service. If the
quantity is too
high, you may
not be able to
recover the re-
frigerant during
service.
--
Bosch Limited