Summary of Contents for Hanwei AT8020

  • Page 1 AT8020 Breath Alcohol Tester Using manual Ver:HW120401146...
  • Page 2 MENU BRIEF INTRODUCTION ............1 MAIN TECHNICAL FEATURE AND DATA ....... 2 CONFIGURATION ..............2 OPERATION ................3 FUNCTION SETUP……………………………………………………………5...
  • Page 3 Brief introduction AT8020 is an advanced portable breath alcohol tester, its core component adopts new high-tech electrochemical sensor which can get more accurate alcohol concentration value, with strong anti-interference ability. The admirable human-device interface makes operation more concise and convenient, the color LCD makes interface more clear and beautiful.
  • Page 4 Main technical data Sensor type: Electrochemical (Fuel cell) sensor Detection Range: 0.000~2.000mg/l (0.40%B.A.C, 4.0‰B.A.C, 4.0g/l) Alarm level: 0.250 mg/L (could be modified) Resolution: 0.01mg/L Display: 1.8 inch LCD screen Work conditions: temperature: 10℃~40℃ humidity: <95%RH (No Dews) Storage conditions: 0℃~50℃ Battery: 3×AAA 1.5V batteries Dimension l×b×h: 114×66×26mm Weight:about 100g(excluding battery)...
  • Page 5 3.2 . Display WAIT BLOW 1. Waiting 2. Counting 3. Result 4. Unit ① 5. Power 6. Blow reminder mg/100mL mg/L Pic 2 Remark①: This battery icon will flash if it’s lack of battery, please change new batteries. If the battery capacity is too low, the tester will be not turn on normally.
  • Page 6 again. 5) If the testing result is lower than the preset alarming level, the indication LED is green; If the testing result reach or exceed the preset level, the indication LED is red, meantime the buzzer will send out rapid alarming sound. 6)...
  • Page 7 5. Function setup In tester turning on status, press button first and then press button to enter into function setup interface (As pic 3). mg/L Pic 3 In function setup functions, press button to choose numbers, button for confirmation, input “1111”(as pic 4) to enter then press into “unit setup”...
  • Page 8 Avoid using the tester when environmental temperature exceeds its specified range.  Any application or fault beyond this manual, please contact with manufacturer or dealer for solutions. Henan Hanwei Electronics Co.,Ltd Add: No.169 xuesong road, national Hi-tech zone, Zhengzhou China 450001 Phone: (86)0371-67169070/80 Fax: (86)0371-67169090 E-mail: sales@hwsensor.com...