Installation Instructions
6200-0 & 6250-0
All fans should be installed by a suitably qualified person in accordance with AS/NZ3000.2000
and relevant building codes. Disconnect supply before making any electrical connections.
For best results provision should be made for return air to enter the room on the opposite
side. In some instances a return air grille/vent may be required.
Installation:
1. This card can be used as a template for making appropriate fan mounting hole size.
2. Cut hole of the required diameter in the desired position in the ceiling.
3. Attach earthed plug base on joist as near as possible to mounting hole.
4. Remove grille by pulling from outside edge.
5. Support fan whilst connecting 3-pin plug to plug base.
6. Insert fan into opening in the ceiling. Push the 3 brackets back through the duct (see diagram). Pull
screws down and tighten until duct is firmly fixed to the ceiling.
Caution:
1. Fan must be mounted at least 120cm above any hotplate and have at least 50cm of clear space
above the fan blades.
2. Do not install in canopies.
3. If ducting is required, its diameter over the full length shall be no smaller than the diameter of the fan
blades and no longer than 1 metre. Restrictions of any kind will affect performance of the fan.
WARNING:
The appliance is not intended for use by children or infirm persons without supervision. Children
should be supervised to ensure they do not play with the appliance.
Cleaning (Ensure fan is unplugged or switched off at mains):
1. Remove grille by pulling outside edge of grille down.
2. Wash grille in hot soapy water and wipe fan blade.
3. Replace grille by pushing grille into fan opening. Fan blade may be removed by undoing screw in the
centre of the fan blade.
TEMPLATE
Centre Hole
Use this template to mark mounting hole for the fan. Use a nail or similar object
to anchor the template at the centre hole, then insert a pencil through the
template at the 245mm or 295mm marking and scribe a circle.
PUSH
6200-0
6250-0
245mm
295mm
PUSH
PULL SCREW DOWN
TIGHTEN
Ceiling
PUSH