MicroCSU/DSU Cards and MicroRacks
LINE RATE MENU—Esc to exit
1. 2400 bps
2. 4800 bps
3. 9600 bps
Circuit Assurance
Choosing option 2 in the Software Switch Menu takes you to the Circuit Assurance
Menu. On dedicated (DDS) circuits, the transmitter and the CTS output can be
configured to go ON only when a working communication circuit is established. If
you use Circuit Assurance with DDS services, enable it on only one end of the
communications link. For Switched-56 services, enable Circuit Assurance on both
ends of the circuit. When Circuit Assurance is disabled, the transmitter and CTS
operate without regard to the receiver state.
CIRCUIT ASSURANCE MENU—Esc to exit
1. Enable Circuit Assurance
2. Disable Circuit Assurance (DEFAULT)
Force RTS
Choosing option 3 in the Software Switch Menu takes you to the RTS Menu. The
RTS input can be forced ON, ignoring the RTS signal from the DTE. When RTS is
forced ON, the transmitter is always enabled and the user may send data.
RTS Menu—Esc to exit
1. RTS Forced On (DEFAULT)
2. RTS Follows DTE Signal
When the Line Rate (Software Switch Menu option 1) is 64 Kbps, RTS is
always forced ON, regardless of the Force RTS switch setting.
24
4. 19.2 Kbps
5. 56 Kbps (DEFAULT)
6. 64 Kbps
Figure 7. Line Rate Menu.