2.7 Programming the MONOLOG

Use the following table and the Master Tag provided for the Programming of this unit.

2.7.1 Enter Main Menu - Program Mode

STEP 1 – Present MASTER TAG to the properly connected Weigand Reader while the system is powered.
RESPONSE – Sound 1 Long and 1 Long Flash – Indicating Master Tag Recognised, awaiting PIN.
STEP 2 – Enter the PIN Code (6 Digit) for the MASTER TAG using the keypad on the Reader.
POSETIVE RESPONSE – Sound 2 Long and 2 Long Flashes – Indicating PIN accepted, entered Main Menu.
NEGATIVE RESPONSE – Stop All Flashes – Indicating Incorrect PIN.
If the response from the unit was Sound 2 Long and 2 Long Flashes the unit entered the Main Menu and would continue
with 2 Long Flashes until a Menu Item are Selected or Escape (ESC) are pressed on the keypad to return to normal
operation.

2.7.2 Menu Items in Main Menu

2.7.2.1 Master Tag Programming (01)

NOTE: The Monolog is limited to 5 Master Tag Program Cycles and after that would not accept Master Tag
Programming Permanently.
STEP 1 – Unit must be in Main Menu – 2 Long Flashes
STEP 2 – Enter 01 on the Keypad.
RESPONSE – Sound 1 Long and continue with 1 Short Flashes – Indicating in " Master Tag
Programming Mode.
STEP 3 – Present new additional MASTER TAG.
STEP 4 – Enter New 6Digit Pin Code for Presented new Master Tag.
RESPONSE – Sound 2 Short and then Change to 2 Long Flashes – Indicating that the new Master Tag
and PIN Code has been Programmed and back into Main Menu

2.7.2.2 Erase All and Reset All to Default (02)

STEP 1 – Unit must be in Main Menu – As in " Enter Main Menu" – 2 Long Flashes
STEP 2 – Enter 02 on the Keypad.
RESPONSE – Sound 2 Long and continue with 2 Short Flashes – Indicating in " Erase and Default"
and waiting for Enter key to proceed.
STEP 3 – Enter Enter (ENT) on the Keyboard if you agree with Erase and Default Continue.
RESPONSE – Approximately 12 Seconds Later, Sound 2 Short and continue with 2 Long Flashes –
Indicating Erase and Default Complete and back in Main Menu.

2.7.2.3 Erase All Tags Data Only (03)

STEP 1 – Unit must be in Main Menu – As in " Enter Main Menu" – 2 Long Flashes
STEP 2 – Enter 03 on the Keypad.
RESPONSE – Sound 3 Long and continue with 3 Short Flashes – Indicating in " Erase All Tags" and
waiting for Enter key to proceed.
STEP 3 – Enter Enter (ENT) on the Keyboard if you agree with Erase All Tags Continue.
RESPONSE – Approximately 6 Seconds Later, Sound 2 Short and continue with 2 Long Flashes –
Indicating Erase Complete and back in Main Menu.

2.7.2.4 New Tag Programming with PIN (04)

STEP 1 – Unit must be in Main Menu – as in " Enter Main Menu" – 2 Long Flashes
STEP2 – Enter 04 on the Keypad.
RESPONSE – Sound 4 Long and continue with 4 Short Flashes – Indicating in " New Tag
Programming" and waiting for next Tag.
STEP 3 – Present new Tag to Reader
STEP 4 – Enter this Tags PIN Code (4 Digits)
STEP 5 – Enter Enter (ENT) on the Keypad.
RESPONSE – Sound 2 Short and continue with 4 Short Flashes – Indicating Tag and PIN accepted
and Programmed and waiting for next Tag.
Repeat STEP 3 to 5 for all Tags to be programmed
STEP 6 – Enter Escape (ESC) on the Keypad to return to Main Menu
RESPONSE – No Sound but Change to 2 Long Flashes – Indicating back into Main Menu.