3.3 Identifying the Charge Controller
You can identify the charge controller by the type label. The type label is in the
enclosure.
4.
Assembly
4.1 Operator:technical personnel;
4.2 Selecting the Mounting Location
Danger:
Possible fire and explosion hazard
The charge controller enclosure may become hot during operation.
• Do not mount the charge controller on flammable construction material.
• Do not mount the charge controller near highly flammable materials.
• Do not mount the charge controller in potentially explosive areas.
• Do not expose the charge controller to direct sunlight to avoid power
loss due to overheating.
Caution:
Enclosure may become hot to the touch and may cause burns
• Mount the charge controller in such a way that it cannot be touched
inadvertently during operation.
4.2.1 Dimensions
L * W * H: 10.63*5.91*3.46 in
270mm*150mm*88mm
4.2.2 Net Weight
Weight:6.6Lbs or 3kg
4.2.3 Ambient Conditions
• The mounting location and method must be suitable for the weight and dimensions.
• Mount on a solid surface.
• The mounting location should be accessible at all times.
• The charge controller should be easy to remove from the mounting location at any
time.
• The ambient temperature should be between -4 and 140F (-20 and 60 °C) to
guarantee optimal operation.