Ducking Threshold
This modification adjusts the threshold for activating the ducking circuit.
The ducking threshold can be raised or lowered by first removing resistor R333, and then placing a resistor (R) at jumper X303.
To lower the ducking threshold, use a resistor value (R) less than 2k ohms. To raise the ducking threshold, use a resistor value
(R) greater then 2k ohms.

Supplied Hardware

4 rubber feet. For stand-alone installation.
1 rackmount bracket, long. For half-rack (single unit) installations.
1 rackmount bracket, short. For half-rack (single) or dual-mount installations.
2 straddle brackets. For dual-mount or fixed installations.
12 bracket screws, 1/4-in. (6 mm). For securing the brackets to the chassis.
4 rackmount screws, 1 in. (2.5 cm). For mounting the unit in a rack.
4 plastic washers. For use with the supplied rackmount screws.
4 wood screws, 1/2 in. (1.25 cm). For fixed installations.

Rackmount Installation

The SCM262 can be mounted as a single unit or dual-mounted with either another SCM262 or another Shure half-rack unit
such as the SCM268 or DFR11EQ. Attach the rackmount brackets using one of the following methods:
Single unit (half-rack) installation:
1.
Attach the short and long rackmount brackets to the SCM262 with eight (8) of the supplied bracket screws.