!!! WARNING !!!
The damper clamp, must be installed, in a manner, which will
maintain the minimum permanent damper vent opening at all
times. SEE FIGURE 1. See the Decorative Hearth System
Specifications on page 3.
!!! WARNING !!!
The State of Massachusetts requires that the chimney flue
damper, when used with decorative gas appliances, be welded
open or completely removed. In the Commonwealth of
Massachusetts, this appliance must be installed by a licensed
plumber or gasfitter.
!!! WARNING !!!
Improper installation, adjustment, alteration, service or
maintenance, can cause property damage, personal injury or
with this appliance. Installation and service, must be
performed, by a qualified installer, service agency or the gas
supplier.
HIGH ALTITUDE DERATE
In the U.S.A., input BTU shall be de-rated 4% ( 1 orifice size )
per 1000 ft. for altitudes above 2000 ft.. In Canada, input BTU
shall be de-rated 10% ( 2 orifice sizes ) at altitudes from 2000
ft. to 4500 ft..
A
B
C
D
Front Width
=
Center Width
=
Depth
=
All Verona Burners are 8.5 inches deep
Height
=
Minimum 16"
Flue Damper Clamp NOT OPTIONAL !
Minimum 6" larger than unit size
Not Less than unit size
3
FIGURE 1