E N G L I S H
Your D
WALT tool is double insulated in
E
accordance with EN 50144; therefore no
earth wire is required.
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualified electrician.
E
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
For 115 V units with a power rating exceeding 1500 W,
we recommend to fit a plug to BS4343 standard.
Using an extension cable
If an extension cable is required, use an approved
extension cable suitable for the power input of this
tool (see technical data). The minimum conductor
2
size is 1.5 mm
.
When using a cable reel, always unwind the cable
completely.
Also refer to the table below.
26
Conductor size (mm
0.75
1.00
1.50
2.50
4.00
Voltage
Amperes
115
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
230
0 - 2.0
2.1 - 3.4
3.5 - 5.0
5.1 - 7.0
7.1 - 12.0
12.1 - 20.0
Assembly and adjustment
Prior to assembly and adjustment always
unplug the tool.
Selecting the operating mode (fig. B1 & B2)
D25102(K)/D25102C (fig. B1)
The tool can be used in the following operating modes:
Rotary drilling: for screwdriving and for
drilling into steel, wood and plastics
Hammer drilling: for concrete and
.
masonry drilling operations.
D25103K/D25104K/D25203K (fig. B2)
The tool can be used in the following operating modes:
Rotary drilling: for screwdriving and for
drilling into steel, wood and plastics
Hammer drilling: for concrete and
masonry drilling operations.
Hammering only: for light chipping,
chiselling and demolition applications.
2
)
Cable rating (Amperes)
6
10
15
20
25
Cable length (m)
7.5
15
25
30
Cable rating (Amperes)
6
6
6
6
6
6
6
6
6
6
10
15
10
10
15
20
15
15
20
25
20
20
25
-
6
6
6
6
6
6
6
6
6
6
6
6
10
10
10
10
15
15
15
15
20
20
20
20
45
60
6
10
15
15
20
20
20
25
25
-
-
-
6
6
6
6
10
15
15
15
20
20
25
-