4.2.
regularly check the water inlet on the base of the pump to ensure that there are no blockages. to access the impeller, carefully undo
the base hex headed screws and remove the base. clean the impeller and replace the base ensuring that the o ring is correctly
located.
DO NOt dismantle any other part of the unit.
8

6. trOublesHOOtiNG

prOblem
1. Water level below min suction depth.
a. motor operates but
2. Air bubbles in pump accumulated during submersion,
there is no suction.
3. clogged intake filter or discharge pipe.
b. reduced water
1. discharge pipe bent, or pinched.
volume for level
2. discharge pipe too narrow.
of water.
3. Pump partially blocked.
c. the pump will not start
1. no electrical power.
or suddenly stops
2. float not working.
during operation.
3. Impeller is jammed.
eNVirONmeNt prOteCtiON
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
weee reGulatiONs
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
Note: it is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: no liability is accepted for incorrect use of this product.
warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey Group, Kempson way, suffolk business park, bury st edmunds, suffolk. ip32 7ar
01284 757500
Original Language Version
© Jack sealey limited
Cause
or float is incorrectly positioned so pump does not stop
at minimum level and sucks in air.
01284 703534
WPC100.V2, WPC100A.V2, WPC150.V2, WPC150A.V2, WPC235.V2, WPC235A.V2, WPC250, WPC250A
sOlutiON
1. stop the pump.
2. release air by inclining the pump and
re-immersing it in water.
3. remove blockage, and clean the unit.
1. straighten pipe.
2. use wider diameter pipe.
3. clean pump.
1. check cable, plug and fuse.
2. contact authorised service agent.
3. clean the pump.