Specification; Operation; Maintenance - Sealey WPC100A.V2 Instructions For Use Manual

Submersible water pumps
Hide thumbs Also See for WPC100A.V2:

Advertisement

‰ ‰ DO NOt use to pump septic tanks or settling pits. DO NOt pump any liquids other than water.
8
‰ ‰ DO NOt operate the pump out of water. the pump pick up area must be completely submerged during operation.
8
‰ ‰ DO NOt exceed the maximum submersible depth (see specifications: max. suction Height).
8
DO NOt operate the pump during freezing temperatures. DO NOt leave the pump in water that may freeze.
8
DO NOt use in swimming pools if people could come into contact with the water whilst pump is in use.
8
DO NOt use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids.
8
DO NOt carry the pump by its electrical cable, or its outlet pipe. use the handle only.
8
When not in use, switch off pump and remove plug from power supply. rinse pump, drain out any water and store in a frost free, safe
9
location.
warNiNG! DO NOt allow uncontrolled discharge of contaminated water which would pollute the environment.
note: this appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack
of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person
responsible for their safety. children should be supervised to ensure that they do not play with the appliance.
2. iNtrODuCtiON
manufactured from corrosion resistant materials with stainless steel motor case and Noryl base cover. Minimum water depth of just 20mm.
designed for clean water although these pumps will accept small particles up to 5mm. suitable for the effective drainage of cellars, sinks, cisterns,
baths and the general transfer of water. The WPC100A.V2, WPC150A.V2, WPC235A.V2 and WPC250A feature an automatic low water cut-out.

3. speCiFiCatiON

model No.
Cut-Out
WPC100.V2
Manual
WPC150.V2
Manual
WPC235.V2
Manual
WPC250
Manual
WPC100A.V2
Automatic
WPC150A.V2
Automatic
WPC235A.V2
Automatic
WPC250A
Automatic

4. OperatiON

warNiNG! ensure you read, understand and apply safety instructions.
4.1.
fit appropriate discharge pipe to pump outlet and secure with clip. ensure the diameter of the discharge pipe is the same as or
greater than the outlet diameter, as a smaller pipe will adversely effect the pump flow rate.
4.2.
Position the pump in the water accordingly, and place the outlet pipe securely in the discharge receptacle or area. it is recommended
that the pump is sunk with its discharge outlet facing up, to release any trapped air.
4.3.
connect the pump to the electrical mains supply and switch it on.
The automatic versions will automatically turn on as the level of water rises (fig.1.A). As the water level lowers, the float will
automatically switch the pump off as it reaches the minimum height (fig.1.B). The float may be adjusted by shortening or lengthening
the cable. The pump will switch on if the water level is up to or above the maximum length of the float cable. To function correctly the
float must move freely. Ensure the float can do so and that the cable is not restricted. Check that the pump and discharge are working
correctly.
4.4.
the water into which the pump is placed will act as the motor's cooling agent. for this reason the pump must remain submerged at all
times. should the pump have to be used in shallow water, DO NOt operate it for more than 10 minutes. Failure to follow this rule will
damage the unit and will invalidate the warranty.
NOTE: See fig.2 to determine minimum clearance required if using pump in a restricted area, i.e. a well, etc.
fig.1

5. maiNteNaNCe

warNiNG! With the exception listed below, all pump, float and electrical cable service maintenance and repair must only be
undertaken by an authorised service agent. failure to observe this rule may be dangerous and will invalidate the warranty.
warNiNG! ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.
4.1.
Keep all parts of the pump clean. rinse, drain and allow to dry before storing the pump.
Original Language Version
© Jack sealey limited
Outlet OD
maximum
maximum
Output
32mm
100ltr/min
32mm
167ltr/min
38mm
208ltr/min
38mm
250ltr/min
32mm
100ltr/min
32mm
167ltr/min
38mm
208ltr/min
38mm
250ltr/min
WPC100.V2, WPC100A.V2, WPC150.V2, WPC150A.V2, WPC235.V2, WPC235A.V2, WPC250, WPC250A
motor
input
Head
particle size
6.0mtr
250W
230V
8.0mtr
500W
230V
8.5mtr
750W
230V
9.5mtr
900W
230V
6.0mtr
250W
230V
8.0mtr
500W
230V
8.5mtr
750W
230V
9.5mtr
900W
230V
maximum
minimum
water Depth
5mm
20mm
5mm
20mm
5mm
20mm
5mm
20mm
5mm
20mm
5mm
20mm
5mm
20mm
5mm
20mm
maximum
water Depth
5mtr
7mtr
7mtr
5mtr
5mtr
7mtr
7mtr
5mtr
fig.2
Issue: 3(L) - 25/10/17