Service And Maintenance - Festool Syslite Duo Original Operating Manual

Hide thumbs Also See for Syslite Duo:
Table of Contents

Advertisement

Available languages

Available languages

6.1
Switch on/off
Switching on the device
The power plug of the device may not be
plugged in in a moist environment, as it does
not feature a proofing against dampness.
Insert mains plug into socket.
Light cone appears instantly.
Switching off the device
Unplug the mains plug.
Coil mains cord on the stand [1-1]. Pin the end
of the cable into the clam [2-1] .
6.2
Temperature surveillance
When exceeding the temperature limit, the device
automatically reduces luminosity. If device continu-
ally exceeds temperature limits, power is cut off
completely.
Measures for restoring luminosity:
Pull mains plug,
remove cause of overtemperature (i. e. ob-
structed air vents),
reinsert mains plug.
Full luminosity is restored.
7
Setup
Always set up device with stand to keep air
vents air accessible [4-1].
Place on dry, even and stable surface. Do not sus-
pend device from its power cord. Electrical hazards
by overstraining the power cord may occur. Prevent
obstruction of the cooling slits on top and bottom of
the device.
Minimum distance to illuminated sur-
0,2m
faces and combustible materials 0,2
meters.
Set up angles [3]
Device may be set up in three different angles.
7.1
Affixing to surfaces [4]
For securer mounting the device is outfitted with a
detachable stand [4-2] that includes bolt holes [4-
3] for secure attachment to surfaces.
Pull off stand. Begin by pulling more strongly on
one side.
Evenly pull off stand.
Affix stand to surface.
Do not affix device to vertical surfaces (walls
etc.) as this significantly reduces the cooling
performance of the air vents.
Mount device on stand.
7.2
Set up with tripod [5]
Use device only with the Festool tripod ST
DUO 200. Tripod height may not exceed 2,0
m. Observe the instructions in the tripod
manual.
Expand tripod legs completely [5].
Mount device on tripod.
Swivel flood light until catch snaps into place.
7.3
Suspend
from wall [6]
Use wall peg [2-1] on rear side of device. Place on
nail or screw head which protrudes from a wall.
by rope [7]
Device can be suspended from a rope via the guid-
ing groove [7-1] located on handhold.
8

Service and maintenance

WARNING
Risk of injury, electric shock
Always disconnect the mains plug from the
socket before performing maintenance work on
the machine!
All maintenance and repair work which requires
the motor housing to be opened must only be
carried out by an authorised service workshop.
Service and maintenance
Customer service and repair only
through manufacturer or service
workshops: Please find the nearest
address at: www.festool.com/service
EKAT
Only use original Festool spare parts!
4
Order No. at: www.festool.com/service
5
3
2
1
– Always clean the plastic cover on the working
light with soft, dry cloth to prevent any damage.
Do not use solvents.
– To ensure constant air circulation, always keep
the cooling air openings in the device clean and
free of blockages.
9
Environment
Do not dispose of the device in house-
hold waste! Recycle devices, accesso-
ries and packaging. Observe applica-
ble national regulations.
DUO