Page 1
Truma Cooler Portable Fridge / Freezer Operating instructions Models This document is part of the product. Single Zone Models C36 / C44 / C60 / C73 / C105 READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. Dual Zone Models C69 DZ / C96 DZ...
WARRANTY ................11 Safety instructions Trademark information Safety symbols and signal words Truma Cooler referred to as Cooler below. This is the safety alert symbol. This symbol Scope of delivery alerts you to potential hazards that can kill or hurt you and others.
Page 3
Do not store dangerous items inside the their specialist instruction and training, their appliance, such as e.g. spray cans, aerosol knowledge and experience with Truma prod- cans, explosives, and/or flammable liquids / ucts and the relevant standards, can carry propellants.
• Buildup of heat in a vehicle can be extreme. Cable cross 12 V 24 V The appliance will shut down at extreme Section in maximum maximum temperatures if cooling is not possible. mm² (AWG) cable length cable length in m (ft) in m (ft) •...
Temperature setting Battery protect voltage setting Temperature setting range –22 °C to +10 °C • Press the “Switch compartments / Mode” (-8 °F to + 50 °F) in each compartment button one more time after change °F or °C, to enter battery protect voltage setting. Then •...
Fuse The fuse (6.3 A) may only be replaced by an expert. Emergency Override Switch For normal operation the switch is in the “NOR- MAL USE” position. If an electronic control or display board failure occurs, slide the switch to “EMERGENCY OVERRIDE” position. In this case, the cooler runs with full cooling capacity and may freeze.
Truma Cooler App Instructions Cleaning To control your Truma Cooler with your smart- Dissconnect the appliance from phone you can use the Truma Cooler smart- the power supply before cleaning. phone app of Truma. Clean the appliance inside and outside with a Activate the Bluetooth function of the appliance clean damp cloth every week.
• Move so appliance is in a lower am- ER 5 bient temperature. Over temperature • Clean vents/ensure clear air flow over compressor. If these measures do not remedy the malfunction, contact your dealership, Truma Service or one of our authorized Service Partners.
Technical Data Model C105 C69 DZ C96 DZ Single Single Single Single Single Dual Dual Zone Zone Zone Zone Zone Zone Zone Dimen- Length Length Length Length Length Length Length sions in 652 (25.7) 652 (25.7) 732 (28.8) 732 (28.8) 912 (36) 732 (28.8) 912 (36)
Truma. Other costs of diagnosis are not included of Truma and the customer’s exclusive remedy in this warranty. At the discretion of Truma, the re- for damages from any cause related to or arising placement of the Product or parts or components...
Page 12
In case you encounter any problems, please contact the Truma Service Center at 855-558-7862 or one of our authorized service partners. For details see www.truma.net. Please have the model number and serial number (see type plate) handy when you call.
Need help?
Do you have a question about the Cooler C36 and is the answer not in the manual?