S I T E P R E P
3 . C H E C K T H E W A T E R S U P P LY
 Water supply meets local plumbing codes.
 Water shutoff in base cabinet, as shown,
or accessible area.
 Access hole through the cabinet is within 1/2"
(1.3 cm) of the rear wall.
 Install any additional tubing only where
temperatures remain above freezing.
Check for leaks.
 Not using a piercing-type or 3/16" (4.76 mm)
saddle valve. See refrigerator dealer for
saddle-type valve kit that complies with
local plumbing codes.
 If water pressure to reverse osmosis system
is less than 40 to 60 psi (276 to 414 kPa):
• Check sediment filter to see if it is blocked.
Replace filter if necessary.
• Allow the storage tank to refill after
heavy usage.
• Remove the water filter cartridge.
No filter bypass is necessary.
I F YOU HAVE Q U E ST IO NS AB OUT YOU R WATE R SU PPLY,
?
CAL L A LIC E NSE D, Q UA L IF I E D PLUM BER
W A T E R S U P P LY R E Q U I R E M E N T S
Water Pressure
30 – 120 psi (207 – 827 kPa)
Water Pressure to
Minimum 40 – 60 psi
Reverse Osmosis
(276 – 414 kPa)
System
Excess Water Line
30" (76.2 cm)
for Connection
Supply
1/4" OD copper, braided
stainless steel or PEX tubing
Water shutoff
(within 1/2" of rear wall)