Functions

2.3 Application Scenario

The optimizer is mandatory and used for all PV modules. It performs the functions of MPPT,
module-level shutdown, monitoring, and automatic positioning.
Figure 2-3 Application scenario
(1) Inverter
Issue 04 (2019-07-05)
Module-level MPPT: The optimizer improves the energy yield of the PV system by
continuously tracking the MPP of each PV module.
Module-level shutdown: The optimizer cuts off the voltage of each PV module.
Module-level monitoring: The optimizer monitors the operating status of each PV
module.
Automatic physical positioning: The optimizer determines the PV module location by
automatic physical positioning.