Safety Notes
Rotational Laser Level
All instructions must be read and observed
in order to work safely with the measuring
tool. The integrated protections in the
measuring tool may be compromised if the
measuring tool is not used in accordance
with the instructions provided. Never make warning signs
on the measuring tool unrecognisable. STORE THESE IN-
STRUCTIONS IN A SAFE PLACE AND INCLUDE THEM WITH
THE MEASURING TOOL WHEN GIVING IT TO A THIRD PAR-
TY.
 Caution – The use of other operating or adjusting
equipment or the application of other processing meth-
ods than those mentioned here can lead to dangerous
radiation exposure.
 Do not make any modifications to the laser equipment.
 Do not use the laser viewing glasses as safety goggles.
The laser viewing glasses are used for improved visualisa-
tion of the laser beam, but they do not protect against laser
radiation.
 Do not use the laser viewing glasses as sun glasses or in
traffic. The laser viewing glasses do not afford complete
UV protection and reduce colour perception.
 Have the measuring tool repaired only through quali-
fied specialists using original spare parts. This ensures
that the safety of the measuring tool is maintained.
 Do not operate the measuring tool in explosive environ-
ments, such as in the presence of flammable liquids,
gases or dusts. Sparks can be created in the measuring
tool which may ignite the dust or fumes.
 Do not open the battery pack. Danger of short-circuiting.
Protect the battery pack against heat, e.g.,
against continuous intense sunlight, fire, water,
and moisture. Danger of explosion.
 Keep the battery pack when not being used away from
paper clips, coins, keys, nails, screws or other small
metal objects that can make a connection from one ter-
minal to another. Shorting the battery terminals together
may cause burns or a fire.
 Under abusive conditions, liquid may be ejected from
the battery pack; avoid contact. If contact accidentally
occurs, flush with water. If liquid contacts eyes, addi-
tionally seek medical help. Liquid ejected from the bat-
tery may cause irritations or burns.
 Recharge the battery pack only with the chargers spec-
ified by the manufacturer. A charger that is suitable for
one type of battery pack may create a risk of fire when used
with another battery pack.
 Use only original Bosch battery packs with the voltage
listed on the nameplate of your measuring tool. When
using other battery packs, e.g. imitations, reconditioned
Bosch Power Tools
battery packs or other brands, there is danger of injury as
well as property damage through exploding battery packs.
Keep the laser target plate 43 and the ceil-
ing measurement plate 44 away from cardi-
ac pacemakers. The magnets on the laser tar-
get plate and on the ceiling measurement plate
generate a field that can impair the function of
cardiac pacemakers.
 Keep the laser target plate 43 and the ceiling measure-
ment plate 44 away from magnetic data medium and
magnetically-sensitive equipment. The effect of the
magnets on the laser target plate and on the ceiling meas-
urement plate can lead to irreversible data loss.
GRL 250 HV
 The measuring tool is provided with a warning label
(marked with number 20 in the representation of the
measuring tool on the graphics page).
Laser Radiation Class 2
do not stare into beam
IEC 60825-1:2007-03
<1mW, 635 nm
 If the text of the warning label is not in your national
language, stick the provided warning label in your na-
tional language over it before operating for the first
time.
Do not direct the laser beam at persons
or animals and do not stare into the di-
rect or reflected laser beam yourself, not
even from a distance. You could blind
somebody, cause accidents or damage
your eyes.
 If laser radiation strikes your eye, you must deliberate-
ly close your eyes and immediately turn your head
away from the beam.
 Do not allow children to use the laser measuring tool
without supervision. They could unintentionally blind
other persons or themselves.
English | 19
1 609 92A 263 | (7.12.15)

Advertisement

loading

Summary of Contents for Bosch GRL 300 HV

  • Page 1  Use only original Bosch battery packs with the voltage listed on the nameplate of your measuring tool. When using other battery packs, e.g. imitations, reconditioned Bosch Power Tools 1 609 92A 263 | (7.12.15)
  • Page 2  Charge only Bosch NiCd/NiMH batteries. The battery protection devices in order to avoid dangers.  Always set up the measuring tool in such a manner that voltage must match the battery charging voltage of the charger.
  • Page 3: Product Description And Specifications

    20 Laser warning label THESE INSTRUCTIONS FOR FUTURE REFER- 21 Warning label, laser radiation exit opening ENCE. (GRL 300 HV/GRL 300 HVG) 22 Battery charger* 23 Mains plug of the battery charger*  Have the remote control repaired only through a quali-...
  • Page 4 * The accessories illustrated or described are not included as standard delivery. Technical Data Rotational Laser Level GRL 250 HV GRL 300 HV GRL 300 HVG Article number 3 601 K61 6.. 3 601 K61 5.. 3 601 K61 7..
  • Page 5: Operation

    37 or to the – To change the battery pack 13, turn the locking knob 16 to wall mount with alignment unit 39. position and pull out the battery pack 13. Bosch Power Tools 1 609 92A 263 | (7.12.15)
  • Page 6 When pressing operation indicator 30 indicates that a signal was sent out. the line operation button a third time, the measuring tool switches to point operation after brief post-pulsation. 1 609 92A 263 | (7.12.15) Bosch Power Tools...
  • Page 7 Wand A auf einem Stativ 37 (Zubehör) oder stellen Sie ously lights up green, and the shock-warning function is ac- es auf einen festen, ebenen Untergrund. Schalten Sie das tivated after 30 seconds. Messwerkzeug ein. Bosch Power Tools 1 609 92A 263 | (7.12.15)
  • Page 8 If the measuring tool should exceed the maximum deviation in any one of the four measuring procedures, have it checked at a Bosch after-sales service agent. – Without turning the measuring tool, position it close to wall B. Switch the measuring tool on and allow it to level in.
  • Page 9 This eliminates the necessity of precisely adjusting the measuring tool. measuring tool to the height to be projected. The right angle to the plumb beam 9 is indicated by the varia- ble laser beam 6. Bosch Power Tools 1 609 92A 263 | (7.12.15)
  • Page 10: Maintenance And Service

    Do not immerse the rotational laser level, battery charger and Bosch’s application service team will gladly answer questions remote control into water or other fluids. concerning our products and their accessories. Wipe off debris using a moist and soft cloth. Do not use any In all correspondence and spare parts orders, please always cleaning agents or solvents.
  • Page 11 The rotational laser level, battery charger, remote UB 9 5HJ control, batteries, accessories and packaging should At www.bosch-pt.co.uk you can order spare parts or arrange be sorted for environmental-friendly recycling. the collection of a product in need of servicing or repair.
  • Page 12: Avertissements De Sécurité

     N’utiliser que des packs d’accus d’origine Bosch dont la tentivement toutes les instructions et te- tension est indiquée sur la plaque signalétique de l’ap- nez-en compte.

This manual is also suitable for:

Grl 250 hvGrl 300 hvg