Please read prior to installation
WHAT'S IN THE BOX:
1 x EBE Express Boiling Unit
1 x EBE 01 Express Boiling Tap
1 x EB FM 350 kPa PLV
1 x EB 316 Brass fitting kit
1 x Boiling Water Warning Label
Important
This unit must be installed by an authorised plumber
The unit to be connected in accordance with AS 3500.4.1
or AS/NZS 3500.4.2
Do not turn on power to this boiler until water is flowing
from the tap
Please leave these instructions with the owner
Water boilers
|
Water chillers
|
Boil/Hot units
|
Boil/Hot/Chill units
|
Parts & Accessories

Advertisement

loading

Summary of Contents for Ecoboil EBE Express Series

  • Page 1 EBE Express Series Automatic Under Bench Water Boilers Installation and maintenance instructions Please read prior to installation WHAT’S IN THE BOX: 1 x EBE Express Boiling Unit 1 x EBE 01 Express Boiling Tap 1 x EB FM 350 kPa PLV...
  • Page 2: Prior To Installation

    Prior to installation • Minimum Inlet Pressure 260 kPa • We recommend the fitting of a water filter. • Only teflon tape to be used where necessary. Under no circumstances is plumbing paste to be used. • When fitting this unit in a cupboard of small proportions, please note that the unit does omit heat.
  • Page 3 c. Connect the 5/16” pipe from the tap to the boiler outlet. d. Connect the 1/4” pipe from the tap to the Mains water supply using the 350 kPa PLV and brass connectors supplied. e. Push the end of the silicon tube on to the vent pipe of the unit. 5.
  • Page 4: Trouble Shooting

    Water has been Check mains water supply turned off Blocked water filter Replace filter cartridge For more information about Ecoboil and our products, visit our website or contact us: Ecoboil Appliances Limited Phone 09 238 2209 Fax 09 282 4073 Mail P.O.