Mini-Vault LTV 764 Installation Instructions
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
WARNING: Fixtures must be grounded in accordance with local codes or the National Electrical Code.
!
Failure to do so may result in serious personal injury. All work should be done by a qualified electrician.
SAFETY WARNING: Low voltage fixtures can become very hot depending on the lamp wattage used.
!
Lighted lamp is HOT! Glass lenses and metal areas above and around the lamp can become hot enough to
blister hands. Particular care should be taken not to locate fixtures where small children can reach them if
higher wattages are used. Do not use these fixtures in submersible installations such as fountains or swimming
pools. DO NOT operate luminaires with missing or damaged lens.
MAINTENANCE: To maintain light efficiency and prevent fixture overheating, glass lenses and enclosures must
be kept clean and free of dirt, dust, leaves, trash and mineral deposits from water. For optimum performance a
regularly scheduled maintenance program should be followed.
CAUTION: When relamping fixture avoid touching the lamp envelope with bare hands. If touching the lamp is
necessary during installation, clean the envelope with alcohol and dry with a clean, soft cloth before burning.
Contamination of the envelope may reduce lamp performance.
KEEP THIS SHEET FOR FUTURE REFERENCE.
CAUTION:
To help maintain a clean, dry splice compartment, seal the
conduit entries with RTV.
Do not exceed maximum wattage shown on fixture label.
Tools Required:
Flat Head Screwdriver
1. Excavate hole in desired location approximately 12"
in diameter and about 3" deeper than height of
fixture. Connect housing to conduit system using a
good thread sealant.
Revised 7/16/10
ECN 100715008
P.O. Box 60080 • 16555 East Gale Ave.
City of Industry, California 91716-0080
626/968-5666 • FAX 626/330-3861
IMPORTANT SAFETY INSTRUCTIONS!
!
Make sure all electrical supply is OFF before beginning fixture installation.
F" Hex Wrench
Status 9
Catalog. No
LTV764
Halogen Integral Transformer
Thread Sealant
. Backfill hole with sand/gravel and soil for stability.
2
Do not backfill hole with bark or vermicolite. (May be
installed in concrete, for paved area installation use
Trim Ring, part no. TR60.)
LTV764
LAMP INFORMATION
Lamp Type Maximum Watts
MR16
50
RTV Sealant
Part No. 95596
Need help?
Do you have a question about the KIM LIGHTING Mini-Vault LTV 764 and is the answer not in the manual?