Pentair Evolio 255 Series User Manual page 12

With logix 740-760 series controllers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
User Guide Evolio
5 .
Programming
5.1.
Home screen
1.
Hourglass
2.
Cursor
3.
Days of the week
4.
Locked/unlocked
indicator
5.
Colon
6.
Indicator
7.
"PM"
8.
"MIN"
9.
"g/L"
10. "KG"
11. "x100"
12. "Lbs/ft3"
13. Faucet
14. Maintenance interval
15. Digits
16. Number
17. History values (H)
18. Parameter (P)
19. Cycle (C)
20. "x2"
21. Hardness
22. Capacity
12 / 116
Displayed when the motor is running. The camshaft should be turning.
These cursors appear next to the item that is currently displayed.
Displayed days of the week. The flag below the day appears when that day has
been programmed as a day the system should regenerate (used with 7-day timer
programming).
This symbol is displayed in basic programming when the current parameter is
locked-out (lock/unlock parameter in advanced programming menu.
Colon flashes as part of the time display.
It also indicates normal operation.
Calendar override icon.
Indicates that the time displayed is between 12:00 noon and 12:00 midnight.
"PM" indicator is not used if the clock mode is set to 24-hour (there is no PM
indicator).
Indicates that the value entered/displayed is in minute increments.
Indicates that the value entered/displayed is in grams/Liter.
Indicates that the value entered/displayed is in kilograms or kilograins,
depending on selected unit mode in P9.
x100 multiplier for large values.
Indicates that the value entered/displayed for regenerant amount is in pounds per
cubic foot.
Appears when the current flow rate is displayed.
The controller may show the faucet and "0", indicating no flow.
Displayed when the duration in month since last maintenance exceed the value
programmed in parameter P11.
Four digits used to display the time, program value or error codes.
Used with #19, #21 and #22.
Displays a sequence number or value.
The number displayed by #18 identifies which history value is currently displayed.
Displayed only in advanced programming.
The number displayed by #18 identifies which parameter is currently displayed.
The number displayed by #18 is the current cycle in the regeneration sequence.
Indicates a second regeneration has been called for.
Hardness setting in mg/L as CaCO
Shows estimated system capacity.
or ppm.
3
Ref. MKT-UG-037 / C - 14.11.2019