Download Print this page

Head Assembly - Pentair Pool Products CodeLine 40E30N Series User Manual

Ro pressure vessel

Advertisement

1.
Use only head components in as-new condition. Use
new O-rings each time the head is assembled.
2.
Cover O-rings with a this even layer of Parker Super
TM
O-Lube silicon lubricant or the lubricant recomm-
ended by your element supplier.
Lubricating Plug seals and O-rings
NOTE
Glycerine is a commercially available
lubricant that will not foul elements.
However, silicon lubricant is
recommended for this application.
3.
Assemble the Adapter Seal into the groove in the
End Plug.
Inserting Adapter seal

Head Assembly

4.
Insert the Head Seal O-ring into the groove on the
outside diameter of the End Plug.
5.
Inserting Head seal
Protect heads from contamination until ready to
assemble into the vessel(s).
Page 8 of 9

Advertisement

loading