Transmit Frequency – Program the transmit frequency
for this channel. Enter in Hz or in MHz. The frequency will
ATFT
automatically be saved in non-volatile memory (flash) for
this current channel number.
Receive Frequency – Program the receive frequency for
this channel. Enter in Hz or MHz. The frequency will
ATFR
automatically be saved in non-volatile memory (flash) for
this current channel number.
TX and RX Frequency – Program the receive and
transmit frequency for this channel. Enter in Hz or MHz.
Same as issuing an ATFR and an ATFT command. User
ATFX
cannot change frequency in the MURS version of the
product. Use ATHP to change channels in the MURS
version.
Group Number – Set or read the unit's Group Number. 0
ATGP
means this feature is not used. If GP is set to any number
other than 0, then all radios communicating with this unit
must have the same group number programmed into them.
Channel Number – Select separate channels to minimize
ATHP
interference between multiple sets of modules operating in
the same vicinity.
Show History – Show a table of listing the most recent
ATHS
receptions, and the IDs that the data was sent from
Configure the I/O The proper hardware option must be
ATIO
installed in the modem. All RV-M7 modems support RS-232
mode. –GX version use IO mode 5. Do not change this.
Read Current Draw Read the current draw in mA.
ATIC
Accuracy is within 20% of actual current draw.
Read/set the CTS threshold – Set the serial buffer
ATJF
threshold where the CTS line is negated. By default the
ATJF level is at 80% of the internal buffer size.
Enable/Disable the LEDs – 1 = LEDs always off. This
ATL
reduces some power consumption. 0 = LED operate
normally.
Address Mask – Configures local and global receive
address space. Each digit may be a
ATMK
0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,or F. In most applications,
this is kept at F000. Set to 0000 to ensure the unit receives
data from ALL other radios, regardless of the TOID in the
transmission.
Unit Address – Configures the individual; address for this
ATMY
unit. Each digit may be a 0,1,2,3,4,5,6,7,8,9,A,B,C,D,E,or F.
Note: FF is interpreted as a group. See addressing section.
ATNB
Parity – Selects parity format. Settings 0-4 transfer 8-bits
over antenna port and generate the parity bit on the RF
receiving side.
ATND
Number of Data Bits – Set/read the number of data bits.
ATNS
Stop Bits – Selects the number of stop bits.
Packet Error Display –
ATPE
packet-error rate. Displays Packets Per Minute (PPM) and
a running total.
Version C16. February 2013
Company Confidential
Shows statistics to compute
Raveon Technologies Corporation
Range:
See product data
sheet. For MURS products,
data sheet.
frequency cannot be changed.
Range:
See product data
sheet. For MURS products,
data sheet.
frequency cannot be changed.
Range:
See product data
sheet.
Range 0-255
Range: 1 - 6
No parameter
Range: 0 - 5 0=RS-232
1=Ethernet 2=RS485 dup
3=RS485 simplx 4=RS422
5=GPS
Range: 0-9999
1
- 2000
0 or 1
Range: 0000 - FFFF
Range: 0000 - FFFF
Range: 0 – 5
0 = none
1 = Odd
2 = Even
3 = Mark (1)
4 = Space (0)
Range: 5 - 8
Range: 1-2
None (display PER)
1 = reset counters
2 = Stop PER display
See
product
See
product
N/A
0
1
0
N/A
3800
0
F000
0001
0
8
1
None