Nice Maestro300 Instructions And Warnings For Installation And Use page 43

Table of Contents

Advertisement

Available languages

Available languages

Example: to adjust the pause time to 40 s.
01. Press the T1 and T2 keys and hold them down for at least 5s
02. Release T1 and T2
03. Press T1 three times
All the parameters can be adjusted as required without any contraindica-
tion; only the adjustment of the "motor force" could require special care:
• Do not use high force values to compensate for the fact that the gate
has anomalous friction points. Excessive force can be detrimental to the
functioning of the safety system or can damage the gate.
• If the "Motor force control" is used in support of the system for impact
force reduction, the force measurement procedure must be performed
after each adjustment, as envisaged by standard EN 12445.
• Weather conditions may affect the movement of the gate. Periodically
you may need to readjust.
To program the parameters in Table 4:
01. Press T1 and T3 together (fig. 21) on the radio transmitter for at least
5 s.
02. Release the two keys.
03. Within three seconds, carry out the action set out in Table 4 based on
the parameter to change.
Parameters
Pause time
Pedestrian opening
Motor force
Step-by-Step (SbS) function
(*)
Original factory value
Parameters
SbS input configuration on the control unit
Flash output configuration
Motor 1 and Motor 2 discharge in closure
Motor 1 and Motor 2 discharge in opening
(*)
Original factory value
N° Valore
1
10s
2
20s (*)
3
40s
4
80s
1
Open 1 leaf halfway
2
Fully open 1 leaf (*)
3
2 leaves partially opened to 1/4 of the full course
4
2 leaves partially opened to half of the full course
1
Low
2
Medium low (*)
3
Medium high
4
High
1
"Open", "Stop", "Close", "Stop"
2
"Open", "Stop", "Close", "Open" (*)
3
"Open", "Close", "Open", "Close"
4
Open only
N° Value
1
Step-by-Step (*)
2
pedestrian opening
1
Flashing light (*)
2
Courtesy light
3
Gate open indicator
1
No discharge (*)
2
0.1s (Minimum)
3
0.2s
4
0.3s
5
0.4s (Medium)
6
0.5s
7
0.6s
8
0.7s (Maximum)
1
No discharge (*)
2
0.1s (Minimum)
3
0.2s
4
0.3s
5
0.4s (Medium)
6
0.5s
7
0.6s
8
0.7s (Maximum)
Example: to adjust the closing discharge of motors 1 and 2 to level 4.
01. Press the T1 and T3 keys and hold them down for at least 5s
02. Release T1 and T3
03. Press T3 four times
21
TABLE 3
Action: operation to be carried out at step 3 in
the recognition phase
Press T1 once
Press T1 twice
Press T1 three times
Press T1 four times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
TABLE 4
Action to perform
Press T1 once
Press T1 twice
Press T2 once
Press T2 twice
Press T2 three times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T3 five times
Press T3 six times
Press T3 seven times
Press T3 eight times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
Press T4 five times
Press T4 six times
Press T4 seven times
Press T4 eight times
T1
T3
English – 15