  • Page 1 3 6" P ROF E SS I ONA L CO OKTOP S & BAC KGUAR DS — CPV2-364GD, CPV2-366, BGCV2-1236, BGCV2-3036 & BGCV2-3036H models P L ANNI NG GU I DE...
  • Page 2: Table Of Contents

    CONTENTS 36" Professional Cooktops PAGE CPV2-364GD, CPV2-366 Key Design Decisions Ventilation Requirements 36" Professional Cooktop CPV2-364GD Product & Cavity Dimensions Clearance Dimensions Cavity Preparation 36" Professional Cooktop CPV2-366 Product & Cavity Dimensions Clearance Dimensions Cavity Preparation 36" Professional Range Backguard...
  • Page 3 IMPERIAL...
  • Page 4: Cpv2-364Gd, Cpv2-366

    KEY DESIGN DECISIONS 36" Professional Gas Cooktop Model no: INSTALL TYPE REAR SURFACE BACKGUARD OPTIONS CPV2-364GD, CPV2-366 BGCV2-3036H BGCV2-3036 HIGH SHELF BACKGUARD MIN 6" CLEARANCE COMBUSTIBLE WALL LOW SHELF BACKGUARD NO BACKGUARD BGRV2-1236 CUSTOM BACKGUARD* MIN 30'' LOW BACKGUARD MAX 15/16''...
  • Page 5: Ventilation Requirements

    VENTILATION REQUIREMENTS 36" Professional Gas Cooktop Model no: INSTALL TYPE HOOD SURROUND MATERIAL CPV2-364GD, CPV2-366 Note: CPV2-366 illustrated but all dimensions apply to the above models Specifications 23" 23" Ventilation Unit Wall Installation Wall Chimney Hood 23'' Deep x Unit Width...
  • Page 6: 36" Professional Cooktop

    PRODUCT & CAVITY DIMENSIONS 36" Professional Gas Cooktop Model no: CPV2-364GD Product Dimensions A Height below countertop datum to bottom of chassis B Overall height of product (bottom of chassis to top of grates) 9 15/16'' C Overall width of cooktop 35 7/8'' 28 1/8'' D Overall depth of cooktop...
  • Page 7: Clearance Dimensions 7

    CLEARANCE DIMENSIONS 36" Professional Gas Cooktop Model no: CPV2-364GD MINIMUM CLEARANCE: MINIMUM CLEARANCE: NEAREST VERTICAL NEAREST VERTICAL MINIMUM CLEARANCE: COMBUSTIBLE SURFACE COMBUSTIBLE SURFACE COMBUSTIBLE SURFACE Cabinetry Dimensions A Minimum width of ventilation hood installed above cooktop 36'' - not shown* B Minimum vertical distance between countertop and cabinet 18'' extending above counter...
  • Page 8: Cavity Preparation 8

    CAVITY PREPARATION 36" Professional Gas Cooktop Model no: CPV2-364GD Cavity Dimensions A Overall height of cutout B Overall width of cutout min 36'' C Overall depth of cutout for projecting control panel 24 3/16'' Overall depth of cutout for flush control panel 26 11/16'' ELECTRICAL &...
  • Page 9: Product & Cavity Dimensions

    PRODUCT & CAVITY DIMENSIONS 36" Professional Gas Cooktop Model no: CPV2-366 Product Dimensions A Height below countertop datum to bottom of chassis B Overall height of product (bottom of chassis to top of grates) 9 15/16'' C Overall width of cooktop...
  • Page 10: Clearance Dimensions

    CLEARANCE DIMENSIONS 36" Professional Gas Cooktop Model no: CPV2-366 MINIMUM CLEARANCE: MINIMUM CLEARANCE: NEAREST VERTICAL NEAREST VERTICAL MINIMUM CLEARANCE: COMBUSTIBLE SURFACE COMBUSTIBLE SURFACE COMBUSTIBLE SURFACE Cabinetry Dimensions A Minimum width of ventilation hood installed above cooktop 36'' - not shown*...
  • Page 11: 36" Professional Cooktop

    CAVITY PREPARATION 36" Professional Gas Cooktop Model no: CPV2-366 Cavity Dimensions A Overall height of cutout B Overall width of cutout min 36'' C Overall depth of cutout for projecting control panel 24 3/16'' Overall depth of cutout for flush control panel 26 11/16'' ELECTRICAL &...
  • Page 12 12'' B Overall width of backguard 35 7/8'' C Overall depth of backguard 15/16'' 35 7/8'' NOT TO SCALE CPV2-366 DATUM : BACK OF PRODUCT PLAN VIEW DATUM : BACK OF PRODUCT 15/16'' 12'' DATUM : BOTTOM OF PRODUCT PROFILE VIEW...
  • Page 13 G Distance from top of backguard to bottom of racks 10 15/16" H Distance from bottom of backguard to bottom of racks 19 1/16" PLAN VIEW CPV2-366 I Distance from top of backguard to top of brackets 5 7/8" DATUM : BACK OF PRODUCT 35 15/16"...
  • Page 14: Product Dimensions

    G Distance from top of backguard to top of racks 5 3/8" H Distance from bottom of backguard to bottom of racks 18 7/8" PLAN VIEW CPV2-366 DATUM : BACK OF PRODUCT 35 7/8" 15/16" 30" DATUM : BOTTOM OF PRODUCT...
  • Page 15 METRIC...
  • Page 16 KEY DESIGN DECISIONS 36" Professional Gas Cooktop Model no: INSTALL TYPE REAR SURFACE BACKGUARD OPTIONS CPV2-364GD, CPV2-366 BGCV2-3036H BGCV2-3036 HIGH SHELF BACKGUARD MIN 152mm CLEARANCE COMBUSTIBLE WALL LOW SHELF BACKGUARD NO BACKGUARD BGRV2-1236 CUSTOM BACKGUARD* MIN 762mm LOW BACKGUARD MAX 24mm...
  • Page 17 VENTILATION REQUIREMENTS 36" Professional Gas Cooktop Model no: INSTALL TYPE HOOD SURROUND MATERIAL CPV2-364GD, CPV2-366 Note: CPV2-366 illustrated but all dimensions apply to the above models Specifications 584mm 584mm Ventilation Unit Wall Installation Wall Chimney Hood 584mm Deep x Unit Width...
  • Page 18 PRODUCT & CAVITY DIMENSIONS 36" Professional Gas Cooktop Model no: CPV2-364GD Product Dimensions A Height below countertop datum to bottom of chassis B Overall height of product (bottom of chassis to top of grates) C Overall width of cooktop D Overall depth of cooktop E Height above countertop datum to top of grates F Height from countertop datum to chassis top surface CABINET FACE FOR...
  • Page 19 CLEARANCE DIMENSIONS 36" Professional Gas Cooktop Model no: CPV2-364GD MINIMUM CLEARANCE: MINIMUM CLEARANCE: NEAREST VERTICAL NEAREST VERTICAL MINIMUM CLEARANCE: COMBUSTIBLE SURFACE COMBUSTIBLE SURFACE COMBUSTIBLE SURFACE Cabinetry Dimensions A Minimum width of ventilation hood installed above cooktop - not shown* B Minimum vertical distance between countertop and cabinet extending above counter C Minimum clearance from left and right edge of range to MAXIMUM OVERALL DEPTH...
  • Page 20 CAVITY PREPARATION 36" Professional Gas Cooktop Model no: CPV2-364GD Cavity Dimensions A Overall height of cutout B Overall width of cutout min 914 C Overall depth of cutout for projecting control panel Overall depth of cutout for flush control panel ELECTRICAL &...
  • Page 21 PRODUCT & CAVITY DIMENSIONS 36" Professional Gas Cooktop Model no: CPV2-366 Product Dimensions A Height below countertop datum to bottom of chassis B Overall height of product (bottom of chassis to top of grates) C Overall width of cooktop D Overall depth of cooktop...
  • Page 22 CLEARANCE DIMENSIONS 36" Professional Gas Cooktop Model no: CPV2-366 MINIMUM CLEARANCE: MINIMUM CLEARANCE: NEAREST VERTICAL NEAREST VERTICAL MINIMUM CLEARANCE: COMBUSTIBLE SURFACE COMBUSTIBLE SURFACE COMBUSTIBLE SURFACE Cabinetry Dimensions A Minimum width of ventilation hood installed above cooktop - not shown* B Minimum vertical distance between countertop and cabinet...
  • Page 23 CAVITY PREPARATION 36" Professional Gas Cooktop Model no: CPV2-366 Cavity Dimensions A Overall height of cutout B Overall width of cutout min 914 C Overall depth of cutout for projecting control panel Overall depth of cutout for flush control panel ELECTRICAL &...
  • Page 24 Product Dimensions A Overall height of backguard B Overall width of backguard C Overall depth of backguard NOT TO SCALE CPV2-366 DATUM : BACK OF PRODUCT PLAN VIEW DATUM : BACK OF PRODUCT DATUM : BOTTOM OF PRODUCT PROFILE VIEW...
  • Page 25 G Distance from top of backguard to bottom of racks H Distance from bottom of backguard to bottom of racks PLAN VIEW CPV2-366 I Distance from top of backguard to top of brackets DATUM : BACK OF PRODUCT INDICATES PRODUCT DATUM -------------------------------------------...
  • Page 26 F Width of racks G Distance from top of backguard to top of racks H Distance from bottom of backguard to bottom of racks PLAN VIEW CPV2-366 DATUM : BACK OF PRODUCT DATUM : BOTTOM OF PRODUCT INDICATES PRODUCT DATUM -------------------------------------------...
  • Page 27 IMPORTANT: The product dimensions and specifications apply at the date of issue. Under our policy of continuous product improvement, these dimensions and specifications may change at any time. Dimensions may vary by ±2mm (1/16"). Please read the installation guide for detailed information on installing the product or visit fisherpaykel.com.