The user guide to the functions and the use of Adax Set Master is
found in the App.
2) The Power output button functions:
•
ADAX SET is switched ON and OFF by holding the Power output but-
ton in for one second.
•
If ADAX SET is ON, it will be switched OFF, and vice versa.
•
ADAX SET reverts to the default settings if the Power output button is
held in for 15 seconds.
Reverting to the default settings may also be carried out via the App.
3) Control by phone call:
ADAX SET may be switched ON and OFF by the Master User calling it.
If it is ON, it will be switched OFF, and vice versa. SMS confirmation of
the action will be received.
4) Signal lamps and warning sounds
Signal
Power
Green lamp
GSM
Blue lamp
Output
Red lamp
5) Troubleshooting checklist:
No. Fault
Green Power lamp is
1
permanently OFF.
24 GB
Mode
OFF
ON
OFF
Flashing
ON
ON
OFF
Possible cause
No external power supply.
Status
No power supply to ADAX SET
Power supply to ADAX SET is OK
-No SIM-card
-Invalid SIM-card
-SIM-card PIN-code not deactivated
-System ON/ OFF switch in OFF position
Searching for network, receiving or transmitting SMS
Coupled to GSM network
ADAX SET's power output ON
ADAX SET's power output OFF
Possible solution
Check the external mains power supply.