Download Print this page

Intertek Jøtul GI 535 DV IPI High Altitude Adjustment Instructions

Manual valve kits

Advertisement

Quick Links

This kit shall be installed by
a qualified service agency in
accordance with the manufacturer's
instructions and all applicable
codes and requirements of the
authority having jurisdiction. If the
information in these instructions
is not followed exactly, a fire,
explosion, or production of carbon
monoxide may result causing
property damage, personal
injury or loss of life. The qualified
service agency is responsible for
the proper installation of this kit.
The installation is not proper and
complete until the operation of
the adjusted appliance is checked
as specified in the manufacturer's
instructions supplied with the kit.
CAUTION: Before proceeding
with this conversion, the gas
supply must be shut off prior to
disconnecting the electrical power.

High Altitude Adjustment

Cet équipement de conversion sera
installé par une agence qualifiée de
service conformément aux instruc-
tions du fabricant et toutes exigences
et codes applicables de l'autorisés
avoir la juridiction. Si l'information
dans cette Instruction n'est pas suivie
exactement, un feu, explosion ou pro-
duction de protoxyde de carbone peut
résulter le dommages causer de pro-
priété, pert ou blessure personnelle
de vie. L'agence qualifiée do service
est esponsable de l'installation pro-
pre de cet équipemetn. L'installation
n'est pas propre et complète jusqu'à
l'operation de l'appareil converi est
chéque suivant les critères établis
dans les instruction de propriétaire
provision nées avel l'équipement.
ATTENTION: Avant de procéder à cette
conversion, l'approvisionnement en
gaz doit être coupée avant de dé-
brancher l'alimentation électrique.
Jøtul North America, Inc. 55 Hutcherson Dr. Gorham, Maine 04038
Instructions
Kit 157886 Manual Valve - LP
Kit 157887 Manual Valve - NG
May, 2016 139778_R01

Advertisement

loading

Summary of Contents for Intertek Jøtul GI 535 DV IPI

  • Page 1: High Altitude Adjustment

    High Altitude Adjustment Instructions Kit 157886 Manual Valve - LP Kit 157887 Manual Valve - NG This kit shall be installed by Cet équipement de conversion sera a qualified service agency in installé par une agence qualifiée de accordance with the manufacturer’s service conformément aux instruc- instructions and all applicable tions du fabricant et toutes exigences...
  • Page 2: High Altitude Installations

    High Altitude Adjustment JØTUL PART ORIFICE SIZE ELEVATION When installing this appliance at altitude above 2000 feet, it is necessary to compensate for the thinner air #48 - Left 2001’- 4500’ 229407 - Left NATURAL #49 - Right (611 - 1170 m) 129411 - Right (less volume of air per cubic foot).
  • Page 3: Gas Pressure Check

    Figure 3. Injector conversion. Pilot Assembly Rear Burner Injector Rear Burner Air Shutter Cable Front Burner Injector Front Burner Air Shutter Cable Air Shutter Adjustor Trays Gas Pressure Check INLET GAS PRESSURES (inches water column) Correct gas pressure is essential for efficient and safe operation of the stove.
  • Page 4 Figure 5. Fig. 6. Pull the tool forward toward you to open the gas Insert the Latch Tool into the receiver hole in cock. Push it back to close the gas cock. the gas cock. Gas Cock Gas cock 1 Gas cock 2...

This manual is also suitable for:

157886157887