The installation shall be carried out in accordance with all applicable installation rules.
Step 1
Locate area that In-Wall amp will be installed.
Step 2
To verify mounting placement of amplifi er/speaker, conduct a stud search to determine stud layout.
For In-Wall Amplifi er scenario, the installer will want to choose a stud bay to mount within, which also
provides access to the AC Outlet/Receptacle that will be used to tap on and power the amplifi er.
Step 3
Once location for the stud placement is identifi ed, place IN-WALL Template on wall and ensure it is
level. Trace outline of template and cut away drywall for in-wall placement. The hole size is 4 1/8"
high x 4 3/16" wide.
Step 4
Install the holding bracket onto the amplifi er using long M3 screws. The fi nger grabs go toward the
RX module. Install the drywall clamps onto each side of the amplifi er as shown below. Do not tighten
screws. Put the clamp center peak outward.
up
Step 5
When installed in a wall cavity that is not UL 2043 plenum, and conduit is required, an industry
standard UL approved fl exible conduit with UL approved wire of 14AWG must be used. When
installed in a UL 2043 plenum area, UL 2043 approved products must be used that are inside the
2043 area including fl exible conduit, wire, connectors, zip ties, etc. Peerless has accessory kit
ADS100-PW which is a complete fl exible conduit whip 6 feet long with proper connectors and zip ties
all UL 2043 rated to meet this requirement.
Note: This step needs to be completed by a certifi ed electrician.
Note: Grounding screw is assembled with metal enclosure of the equipment to provide a bonding
terminal means intended to bind a bonding conductor with double crimp-on metal ring terminal.
Double crimp-on metal ring terminal is intended to be secured to enclosure by metal stand, star
washer and screw.
Note: When conduit is not required by code, the user may use Romex or similar (at least 14 AWG
shielded wire stranded or solid) routed from the power source directly to the power input plug for on-
wall use only. Smallest conductor used at fi eld wiring terminals for permanent installation: 14 AWG.
Step 6
Connect power at the amplifi er. For solid wire, simply strip back 1/4" insulation, and insert fi rmly into
the proper polarity cavity. For stranded wire, it's recommended to twist the wire, and also use a small
straight screwdriver to release the clamp. Then, insert the wire. Test all connections by trying to pull
the wire back out. Complete the ground connection to the amplifi er chassis ground location with the
supplied ring terminal, star washer, and M3.5 washer head screw.