INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR INJURY TO PERSONS
WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS: Do Not overdrive fixtures with greater
!
than 12 volts or fixture over-heating and short lamp life will occur. Do Not overload the transformer by
installing (or relamping) higher wattage lamps than planned. Note: Total wattage of all lamps connected to one
transformer must not exceed the capacity of that transformer. Do Not install luminaire within 10 feet (3.04m) of
a pool, spa, or fountain. DO NOT operate luminaire with missing or damaged lens.
SAFETY WARNING: When relamping be sure electrical supply is OFF. Low voltage fixtures can become
!
very hot depending on the lamp wattage used. Glass lenses and metal areas above & around the lamp can
become hot enough to blister hands. Use discretion when touching fixture and be sure to allow fixture to cool
before relamping. When relamping fixture avoid touching the lamp envelope with bare hands. If touching the
lamp is necessary during installation, clean the envelope with alcohol and dry with a clean, soft cloth before
turning ON. Contamination of the envelope may reduce the lamp performance. To maintain light efficiency and
prevent fixture-overheating, glass lenses and enclosure must be kept clean and free of dirt, dust, leaves, trash
(combustible materials) and mineral deposits from water. Particular care should be taken not to locate fixtures
where small children can reach them if higher wattage's are used.
NOTE: Keep the lamp free from impact while burning, as this may deform the filament and shorten the lamp life.
NOT INTENDED FOR INDOOR USE. All electrical work should be done by a qualified electrician.
KEEP THIS SHEET FOR FUTURE REFERENCE.
INSTALLATION INSTRUCTIONS:
Tools Required:
Phillips Screwdriver
Adjustable Wrench
B" Hex Wrench
Silicone Grease
1. Tighten coupling onto mounting device.
(See KIM Installation Instructions for Low
Voltage Mounting Options, part no. 95488.)
Tension Ring
3. To install lamp, unscrew tension ring. NOTE:
Lamp installation is not accessible by removing
the glass lens.
Revision 7/16/10
ECN
100715008
P.O. Box 60080 • 16555 East Gale Ave.
City of Industry, California 91716-0080
626/968-5666 • FAX 626/330-3861

IMPORTANT SAFETY INSTRUCTIONS!

!
Make certain the electrical supply is OFF before starting fixture installation.
Status 6
Fixture
Coupling
2. Attach fixture onto coupling. NOTE: KIM
"KLV Mounting Options" can be installed
before fixture is attached.
Apply Silicone Grease
IMPORTANT
DRAIN HOLE IN SHIELD
MUST FACE DOWN!
4. Install lamp of type and wattage shown on
fixture label. NOTE: Add silicone grease to
screw threads each time fixture is relamped.
KLV201
Part No. 95613

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KLV201 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for kim lighting KLV201

  • Page 1 City of Industry, California 91716-0080 626/968-5666 • FAX 626/330-3861 KLV201 Accent Light - KLV201 Installation Instructions INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS: Do Not overdrive fixtures with greater than 12 volts or fixture over-heating and short lamp life will occur.
  • Page 2 Additional wire and connectors may be purchased from Kim Lighting: KLV427 #12-2 Cable KLV432 #8-2 Cable KLV410 Connector KLV411 Connector Page 2 Kim Lighting • 16555 E. Gale Ave. • P.O. Box 60800 • City of Industry, CA 91716-0080 • 626/968-5666 FAX 626/330-3861...

Table of Contents