Model Composition
VL-SV30

Specifications

Model number and name
Dimensions
Power supply
Power consumption
Dimensions (H x W x D)
(Excluding protruding sections)
Weight
Operating environment
Display
Talking method
Viewing angle
Installation method
Minimum illuminance required
Lighting method
External material

Wiring schematic diagram

Door station 1
(Non polar)
You can also connect
an optional lobby
station for apartment
complexes.
Main monitor station
(Non polar)
(Non polar)
(Non polar)
Power plug
(100 – 240 V AC)
Installing the Doorphone
• Example: Installation height is 1450 mm (standard position).
Side view
1810 mm
Centre of the
door station
650 mm
66°
Image
range
1450 mm
1160 mm
500 mm
Top view
Image range:
960 mm
87°
500 mm
Important
– Safety Precaution: carefully read the operating instructions and installation manual before using this product.
VL-MV30
Main Monitor Station (Main monitor)
148
36
195
100 – 240 V AC, 50/60 Hz
Standby: Approx. 0.04 A
During operation: Approx. 0.22 A
Approx. 195 x 148 x 36 mm
Approx. 550 g
0 °C to 40 °C, Up to 90 % RH
(Relative Humidity) non condensing
3.5 inch colour LCD monitor
Hands-free
-
Wall mount (Wall mount bracket included)
-
-
Flame retardant ABS resin
Door station 2
(Non polar)
PBX
Terminal box
(4-conductor wiring)
(Door Opener) 1
(Door Opener) 2
Wood screws
Mounting base
Mounting base
VL-MV30 x 1, VL-V566 x 1
VL-V566
Door Station (Doorphone)
Up to 2
99
36.5
131
Supplied by the Main Monitor Station
-
Approx. 131 x 99 x 36.5 mm
Approx. 200 g
-10 °C to 50 °C, Up to 90 % RH
(Relative Humidity) non condensing
-
-
Horizontally: Aprrox. 87˚
Vertically: Approx. 66˚
Wall mount (Wall mount base included)
1 lx (within approx. 50cm from the camera lens)
Infrared LEDs
Flame retardant ABS resin
Wire type and length
• Wire (between the main monitor station and the door station):
Type
General cable CAT-3
General cable 22 AWG (ø 0.65)
• Wire (between the main monitor station and PBX):
Type: General cable CAT-3 or 22 AWG (ø 0.65)
Distance: Maximum 100 m
Door
Door
83.5 mm
Wall
Wire (Not included)
99 mm
24 mm
131 mm
83.5 mm
VL-V590
Optional Lobby Station
180
100 V – 240 V AC, 50/60 Hz
Standby: Approx. 0.02 A
During operation: Approx. 0.03 A
Approx. 358 x 180 x 17.3 mm
(Excluding sections embedded into the wall)
Approx. 2.0 kg
-10 °C to 50 °C, Up to 90 % RH
(Relative Humidity) non condensing
-
-
Horizontally: Aprrox. 87˚
Vertically: Approx. 66˚
Wall mount (Flush mounted box included)
-
-
Stainless steel and flame retardant ABS resin
Distance
Maximum 50 m
Maximum 100 m
Installing the Main Monitor
Wood screws
Mounting
bracket
148 mm
Main Monitor
Mounting bracket
• The actual product may vary slightly from photograph.
• Weights and dimensions are approximate.
• Design and Specifications are subject to change without notice.
• These products may be subject to export control regulations.
MG-DHPL006EN 1410ITP/ZZZ-1
17.3
358
Loop resistance
10 Ω or lower
83.5 mm
Wall
Wire (Not included)
48.4 mm
83.5 mm
195 mm